Air King AK864L Ventilation Hood User Manual


 
CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE
MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES,
OR NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR
WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE
THE SERVICES OF A QUALIFIED ELECTRICIAN.
1. Wiring Fan/Light Independently: Run wiring from an approved
wall switch carrying the appropriate rating. One neutral
(white), one ground (green or bare copper), and two hot
(black lead connected to the switch). Secure the electrical
wires to the housing with an approved electrical connector.
Make sure you leave enough wiring in the box to make the
connection to the fan’s receptacle.
1a. From where you have access to inside the fan’s junction box,
connect the one white wire from the house to both the white
wire from the fan’s light receptacle and the white wire from
the fan’s exhaust receptacle. Connect the first black wire
from the wall switch to the black wire from the fan’s light
receptacle. Connect the second black wire from the house
to the fan’s exhaust receptacle. Connect the ground wire
from the house to the green wire from the fan’s grounding
screw (Figure 9). Use approved methods for all connections.
2. Wiring Fan/Light together: Run wiring from an approved wall
switch carrying the appropriate rating. One neutral (white),
one ground (green or bare copper), and one hot (black lead
connected to the switch). Secure the electrical wires to the
housing with an approved electrical connector. Make sure
you leave enough wiring in the box to make the connection
to the fan’s receptacle.
2a. From where you have access to inside the fan’s junction box,
connect the one white wire from the house to both the white
wire from the fan’s light receptacle and the white wire from
the fan’s exhaust receptacle. Connect the black wire from
the wall switch to both the black wire from the fan’s light
receptacle and the black wire from the fan’s exhaust
receptacle. Connect the ground wire from the house to the
green wire from the fan’s grounding screw (Figure 10). Use
approved methods for all connections.
1b. Mounting Tab Installation: Position housing against the joist
and trace an outline of the housing onto the ceiling material
(Figure 7). Set housing aside and cut opening, being careful
not to cut or damage any electrical or other hidden utilities.
Place housing next to the joist and insure that it is flush with
the finished ceiling. Secure with four screws or nails (not
provided) to ensure proper installation (Figure 5).
SECTION 4
Ducting
CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL
AND NATIONAL BUILDING CODES.
1. Connect the ducting to the fan’s duct collar (Figure 8). Secure
in place using tape or screw clamp. Always duct the fan to
the outside through a wall or roof cap.
NOTE: If damper detaches from unit, reattach by snapping the
collar back onto the unit. It is designed to only fit one way.
SECTION 5
Wiring
CAUTION: MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE STARTING INSTALLATION.