SPECIFICATIONS
RANGE HOOD BLOWERS
PROFESSIONAL
Motor
B300
300 CFM, 1 speed, permanently split capacitor motor.
Rated 120 volts, 60 hz., 0.90 amps.
B500
500 CFM, 2 speed, permanently split capacitor motor.
Rated 120 volts, 60 hz., 1.10 amps.
B600
600 CFM, 3 speed, permanently split capacitor motor.
Rated 120 volts, 60 hz., 1.25 amps.
B900
900 CFM, 3 speed, permanently split capacitor motor.
Rated 120 volts, 60 hz., 5.70 amps.
B1125
1200 CFM, 3 speed, permanently split capacitor motor.
Rated 120 volts, 60 hz., 7.20 amps.
Blower Wheel
Dual inlet, electronically balanced polymetric centrifugal blower
wheel, 5
27
/
32
" width 59 paddles.
Blower Mounting
Easily installs into hood shell through predrilled, threaded and
grommeted bolt holes in shell and includes a Snap-In wiring
harness for electrical connection.
Blower Housing
Constructed of galvanized steel.
B SERIES
Canada: 110 Glidden Road
Brampton, Ontario L6T 2J3
Tel: (905) 456-2033
Fax: (905) 456-1015
U.S.: 820 Lincoln Drive
West Chester, Pennsylvania 19380-4466
Tel: (610) 692-7400 • 877-304-3785
Fax: (610) 696-8048
New 5-07Specifications subject to change without notice.
PROJECT
LOCATION
CONTRACTOR
ARCHITECT
ENGINEER
SUBMITTED BY DATE
FAN MODEL
CFM
IN
RPM WATTS AMPS SONES QTY
OPTIONAL EQUIPMENT
NUMBER NUMBER W.G. & REMARKS
Professional Series
Blowers
CUS
PERFORMANCE
Static Pressure (inches of w.g.) HVI Sones Fan Speed Power
Air Flow - CFM
0 0.1 0.25 0.375 0.5 0.625 1.0 1.25
@ .1 SP RPM Watts
B300
317 300 267 229 167 - - - 1.5 760 81
B500
529 500 444 382 278 116 - - 4.5 1206 131
B600
638 600 537 458 342 143 - - 5.5 1492 164
B900
918 900 874 852 829 805 725 661 11.0 2051 604
B1125
1222 1200 1168 1142 1117 1090 1004 933 15.0 2617 945