Alto-Shaam ASF-60E Fryer User Manual


 
D E L U X E C O N T R O L O P E R A T I O N
P R O G R A M M I N G T H E C O N T R O L
“LO BAND”
“LO BAND” provides an alarm notification when the temperature of the
oil is lower than the set-point temperature. The adjustment range is
between 5°F and 100°F (3°C and 56°C) with a factory preset of 21°F (12°C).
Press the Upor Downarrow keys to scroll until “LO BAND” appears in the display.
Press the Right arrow key to enter the program. Display stops flashing. Press the Up
or Downarrow keys to scroll until the desired number appears in the display. When
the desired setting appears, press the Right arrow key to accept the selection. Display
flashes. Press the Down arrow key to advance the control to the next programming
function.
“HI BAND”
“HI BAND” provides an alarm notification when the temperature of the
oil becomes higher than the set-point temperature. The adjustment range
is between zero and 100°F (38°C) with a factory preset of 25°F (14°C).
Press the Upor Downarrow keys to scroll until “HI BAND” appears in the display.
Press the Right arrow key to enter the program. Display stops flashing. Press the Up
or Downarrow keys to scroll until the desired number appears in the display. When
the desired setting appears, press the Right arrow key to accept the selection. Display
flashes. Press the Down arrow key to advance the control to the next programming
function.
“MELT CT”
The fryer control includes a melt function with ON/OFF pulsed heating cycles for the
purpose of melting solid shortening at a continuous but slower rate to assure full melt-
down. The operator has the ability to control the ON/OFF pulse rate between 00:01 and
00:60 seconds. The factory default is set for 10 seconds (00:10).
Press the Upor Downarrow keys to scroll until “MELT CT” appears in the display.
Press the Right arrow key to enter the program. Display stops flashing. Press the Up
or Downarrow keys to scroll until the desired time appears in the display. When the
desired setting appears, press the Right arrow key to accept the selection. Display
flashes. Press the Down arrow key to advance the control to the next programming
function.
The “PREHEAT BAND” is used to prevent the oil temperature in the frypot from
reaching the actual set-point temperature in order to compensate for temperature override
as the fryer calls for heat. This program feature is set to 10°F (6°C) at the factory.
I t is s tro n gl y ur g ed t ha t the PR EHE AT BA N D” rem ain at t h is s et t in g.
0 : 1 0
Melt Ct
1 0 °F
Preheat Band
2 5 °F
Hi Band
Hi Temp
“PREHEAT
BAND”
To exit the control programming mode, press and hold the LEFTarrow key.
Low Temp
2 1 °F
Lo Band
El ec tr ic Fryer Op er at io n & Ca re M an ua l 40
D E L U X E C O N T R O L O P E R A T I O N