Amana UXG7360V Ventilation Hood User Manual


 
PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS
INSTALLATION DIMENSIONS
LOCATION REQUIREMENTS
UXG7360V
UXG7480V
Electrical: 120-volt, 60-Hz, AC-only, 15-amp fused electrical circuit
is required.
Wall-Mount Canopy Grill Vent Hood
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10153187
02-20-09
X
A
1
8"
(45.7 cm)
12"
(30.5 cm)
4"
(
10.2 cm)
24"
(61.0 cm)
30" (76.2 cm)
36" (91.4 cm)
48" (121.9 cm)
Vented installations
C
anopy grill vent hood location should be away from strong draft
areas, such as windows, doors and strong heating vents.
Venting methods
This canopy grill vent hood is factory set for venting through the roof
or through the wall. A 10" (25.4 cm) round vent system is needed for
installation (not included). The hood exhaust opening is 10" (25.4 cm)
round.
NOTE: Flexible vent is not recommended. Flexible vent creates back
pressure and air turbulence that greatly reduce performance. Vent
system can terminate either through the roof or through the wall. To
vent through a wall, a 90° elbow is needed.
Rear discharge
A 90° elbow may be installed immediately above the hood.
*NOTE:The grill vent hood
duct cover is designed to add
12" (30.5 cm) to meet the
ceiling or soffit height.
Depending on your model,
order:
Part Number W10153151 for
30" (76.2 cm) models,
Part Number W10153152 for
36" (91.4 cm) models,
Part Number W10153153 for
48" (121.9 cm).
IMPORTANT:
Minimum distance “X”:
30" (76.2 cm)
Suggested maximum
distance “X”: 36" (91.4 cm)
M
Roof Venting Wall Venting
A.Optional decorative duct cover
B.10" (25.4 cm) round vent
C.Roof cap
D.10" (25.4 cm) round vent
transition
A.Optional decorative duct cover
B.10" (25.4 cm) round vent and
elbow
C.Wall cap
D.10" (25.4 cm) round vent
transition
A
A
B
B
C
C
D
D
Calculating Vent System Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
Maximum equivalent vent length is 35 ft (10.7 m).
Vent Piece 10" (25.4 cm) Round
45° elbow 2.5 ft
(0.8 m)
90° elbow 5.0 ft
(1.5 m)
1 - 90° elbow = 5.0
M
Example vent system
The following example falls within the maximum recommended
vent length of 35 ft (10.7 m).
R
1 - 90° elbow = 5.0 ft (1.5 m)
1 - wall cap = 0.0 ft (0.0 m)
8 ft (2.4 m) straight = 8.0 ft (2.4 m)
Length of system = 13.0 ft (3.9 m)
90 elbow
6 ft (1.8 m)
2 ft
(0.6 m)
Wall cap
X