Bertazzoni X365GGVCR Range User Manual


 
18
STEP 5: VISUAL CHECKS
Before reinstalling the bottom panel, the
following visual check must be performed to
ensure that the conversion has been carried out
properly and without damage to other
components of the range.
A) CONNECTION OF THERMOCOUPLES TO
THERMOSTAT
The thermocouples for both broiler and main
oven burner are connected to the same magnet.
Tight gently the two connections alternating
action on the two nuts. Do not fully tighten one
thermocouple before having started to tighten
the second one.
B) OVEN IGNITER AND THERMOCOUPLE
POSITION
The appropriate gap between the tip of the spark
plug or thermocouple and the burner shall be
approximately 1/8’’.
The tip of the spark plug or thermocouple must
fully overlap at least the first gas emission hole of
the burner.
After performing all these visual checks, reinstall
the bottom panel of the oven compartment and
proceed to setting the minimum for each
burner.