Broan 678 Ventilation Hood User Manual


 
!
FAN/LIGHT COMBINATION VENTILATORS / VENTILADORES CON LÁMPARA
MODELS / MODELOS 678 • 678MX • 679 • 679FLT • 680 • 680FLT
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the manu-
facturer at the address or telephone number listed in
the warranty.
2. Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting means
to prevent power from being switched on accidentally.
When the service disconnecting means cannot be
locked, securely fasten a prominent warning device,
such as a tag, to the service panel.
3. Installation work and electrical wiring must be done
by a qualified person(s) in accordance with all appli-
cable codes and standards, including fire-rated con-
struction codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting. Follow
the heating equipment manufacturer’s guideline and
safety standards such as those published by the
National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it
must be marked as appropriate for the application and
be connected to a GFCI (Ground Fault Circuit Inter-
rupter) - protected branch circuit.
8. Never place a switch where it can be reached from a
tub or shower.
9. Fluorescent models only: Do not use a dimmer
switch to control the light of this unit.
10. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to
exhaust hazardous or explosive materials and
vapors.
2. This product is designed for ceiling installation
only. This product is designed for installation in
ceilings up to a 12/12 pitch. Ductwork must point
up. DO NOT MOUNT THIS PRODUCT IN A
WALL.
3. To avoid motor bearing damage and noisy and/
or unbalanced impellers, keep drywall spray,
construction dust, etc. off power unit.
4. Please read specification label on product for
further information and requirements.
Installer: Leave this manual with the
homeowner.
Homeowner: Use and Care information
on page 4.
READ AND SAVE THESE
INSTRUCTIONS
TYPICAL INSTALLATIONS
HOUSING
CEILING
JOIST
MOUNTING TABS
GRILLE
CEILING
MATERIAL
POWER CABLE
HOUSING
CEILING
JOIST
MOUNTING TABS
GRILLE
CEILING
MATERIAL
POWER CABLE
4" ROUND
DUCT
ADDITIONAL
FRAMING
HOUSING MOUNTED TO ADDITIONAL FRAMING
Discharge 90
0
to joists.
HOUSING MOUNTED DIRECTLY TO JOIST
2x6 (or larger) Discharge parallel to joists.
HOUSING
2 x 4
CEILING
JOIST or
TRUSS
MOUNTING
TABS
CEILING
MATERIAL
POWER CABLE
ADDITIONAL
FRAMING
2 x 4
CEILING
JOIST or
TRUSS
GRILLE
HOUSING MOUNTED TO 2x4 TRUSS
Requires additional framing for mounting tabs.
Discharge parallel to joists.
HOUSING
MOUNTING
TABS
CEILING
MATERIAL
POWER CABLE
ADDITIONAL
FRAMING
"
I
"
JOIST
"
I
"
JOIST
GRILLE
HOUSING MOUNTED TO “I” JOIST
Requires additional framing for mounting tabs.
Discharge parallel to joists.
HOUSING
2 x 4
CEILING
JOIST or
TRUSS
MOUNTING TABS
CEILING
MATERIAL
POWER CABLE
4" ROUND
DUCT
ADDITIONAL
FRAMING
2 x 4
CEILING
JOIST or
TRUSS
GRILLE
HOUSING MOUNTED TO 2x4 TRUSS
Requires additional framing for mounting tabs.
Discharge 90
0
to joists.
HOUSING
MOUNTING TABS
CEILING
MATERIAL
POWER CABLE
4" ROUND
DUCT
ADDITIONAL
FRAMING
"
I
"
JOIST
"
I
"
JOIST
GRILLE
HOUSING MOUNTED TO “I” JOIST
Requires additional framing for mounting tabs.
Discharge 90
0
to joists.
*
Additional framing must be a 2x6 (minimum height), at
least 9-inches long.
*
*
*
*
ADVERTENCIA
PARA REDUCIR EL RIESGO DE INCENDIO, DESCAR-
GA ELÉCTRICA O LESIONES PERSONALES, OBSER-
VE LO SIGUIENTE:
1. Utilice esta unidad solamente de acuerdo con las
instrucciones del fabricante. Si tiene preguntas
comuníquese con el fabricante a la dirección o al número
telefónico que se indica en la garantía.
2. Antes de dar servicio o limpiar la unidad, interrumpa el
suministro de energía en el panel de servicio y bloquee los
dispositivos de desconexión para evitar la reinstalación ac-
cidental de la energía. Cuando no se puedan bloquear los
dispositivos de desconexión, fije seguramente en el panel
de servicio un medio de advertencia que sea visible, como
por ejemplo una etiqueta.
3. Una persona o personas calificadas deben realizar el
trabajo de instalación y el cableado eléctrico, de acuerdo
con todos los códigos y normas aplicables, inclusive los
códigos y normas de construcción para evitar incendios.
4. Se necesita suficiente aire para que se realice la combustión
y la descarga de gases adecuadas a través de la chimenea
del equipo para quemar combustible a fin de evitar las
corrientes de inversión. Observe los lineamientos del
fabricante del equipo de calefacción y las normas de
seguridad, como por ejemplo las publicadas por la Asociación
Nacional de Protección contra Incendios (National Fire Pro-
tection Association: NFPA), y la Sociedad Americana de
Ingenieros en Calefacción, Refrigeración y Sistemas de
Acondicionamiento de Aire (American Society for Heating,
Refrigeration and Air Conditioning Engineers: ASHRAE), y
los códigos locales.ditioning Engineers (ASHRAE), and the
local code authorities.
5. Cuando corte o perfore la pared o el cielo raso, tenga
cuidado de no dañar el cableado eléctrico ni otras
conexiones de servicios que se encuentren ocultas.
6. Los ventiladores con conductos siempre deben tener salida
hacia el exterior.
7. Si se va a instalar esta unidad sobre una tina o ducha, debe
marcarse que es apropiada para esta aplicación y
conectarse a un GFCI (interruptor accionado por pérdida
de conexión a tierra) en un circuito de derivación protegido.
8. Nunca coloque el interruptor en un lugar en donde se pueda
alcanzar desde la tina o ducha.
9. Modelos fluorescentes solamente: No emplee un
interrupto reductor para controlar la luz de esta unidad.
10. Esta unidad debe conectarse a tierra.
PRECAUCIÓN
1. Esta unidad debe usarse solamente para ventilación gen-
eral. No la utilice para la descarga de materiales ni vapores
peligrosos o explosivos.
2. Este producto está diseñado solamente para instalarse en
el cielo raso. Este producto está diseñado para instalarse
en cielos rasos con una pendiente de hasta 12/12. El sistema
de conductos debe apuntar hacia arriba. NO MONTE
ESTE PRODUCTO EN LA PARED.
3. Para evitar causar daño a los cojinetes del motor y pistones
impulsores ruidosos y/o no balanceados, mantenga los
aerosoles para pirca, el polvo de construcción, etc. lejos del
motor.
4. Por favor consulte la información y los requerimientos
adicionales contenidos en la etiqueta de especificaciones
que se encuentra en el producto.
A la persona que realiza la instalación:
Deje este manual con el dueño de la
casa.
Al dueño de la casa: Las instrucciones
de operación y limpieza se encuentran
en la página 4.
!
LEA Y CONSERVE ESTAS
INSTRUCCIONES
*