Cleveland Range CSTK-610 Oven User Manual


 
Cleveland
P
roject ________________________________
I
tem __________________________________
Quantity _______________________________
FCSI Section ____________________________
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
COMBI OVEN-STEAMER
Stacking Kits for Gas Table Type Models
(OGB 6.10 on OGB 6.10 or OGS 6.10 on OGS 6.10)
SECT. IIB PAGE 5A
0707
by
by
Cleveland
Cleveland
Model # Description
CSTK-610 for mounting two 6.10 models
C
STK-610CA for mounting two 6.10 models (with casters)
U
NIT A
UNIT B
6.00"
NOTE: Overall height of unit does not change for units with casters.
7
RC
CS
W1 W2
D
G
4
.38"
NOTE: Overall height of unit does not change for units with casters.
RC
CS
W
1
W
2
D
G
RC
CS
W1 W2
D
G
4.38"
38.08"
3
9.21"
L
EFT SIDE VIEW
6.10
on 6.10
GAS
6
U
NIT A
UNIT B
3
3
6.70"
1.58"
28.43
5
.00"
1
.82"
67.8 5 "
28.43
6.00"
78.00”(MIN.HOOD REQUIREMENT)
2
.52"
7
UTILITIES (Utility connection shown below are listed per unit)
Required Clearances:
Rear - 2", Left Side - 4", Right Side - 2 1/2"
Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located
next to the unit.
Allow for sufficient clearance on left side for service access (contact the
factor
y ser
vice department for recommendations).
Installation must comply with all local fire and health codes.
Electrical Requirements:
120 volt, 60 Hz, single phase,
UNIT A -
11.7 amps
Do not connect to a G.F.I. outlet.
UNIT B -
11.7 amps
Gas Connection: 3/4" NPT
Gas T
ype:
Natural Gas (Propane optional)
Gas Flow Pressure:
Natural Gas - Min. 5.5" WC / Max. 14" WC
Propane Gas - Min. 11" WC / Max. 14" WC
BOILER MODELS UNIT A - OGB-6.10 UNIT B - OGB-6.10
T
otal Connected Load:
45.400 BTU
45.400 BTU
Steam Generator:
45.400 BTU
45.400 BTU
Hot Air: 45.400 BTU 45.400 BTU
BOILERLESS MODELS UNIT A - OGS-6.10 UNIT B - OGS-6.10
T
otal Connected Load:
45.400 BTU
45.400 BTU
Hot Air:
45.400 BTU 45.400 BTU
W1
W2
D
RC
S
CS
AV
G
E1
E2
W1
W2
D
RC
S
CS
AV
G
E1
E2
Water Connections: Cold Water (drinking water quality)
Flow Pressure:
30 - 60 PSI
W
ater Inlets: 3/4" GHT-F (Female Garden Hose Connection)
T
reated W
ater for Steam Generator
Untreated Water for Condenser
Drain Connection: 2" Tube
V
enting:
Exhaust Hood required
*Connection for Cleaning Solution
*Connection for Rinse Cycle
*
Available as an option
Note: For additional connection details, see spec sheet for each
individual combi model to be stacked.
W1
W2
D
RC
S
CS
AV
G
W1
W2
D
RC
S
CS
AV
G
E1
W1
W2
D
RC
S
CS
AV
G
E1
E2
W1
W2
D
RC
S
CS
AV
G
W1
W2
D
RC
S
CS
AV
G