Conair WSB Blender User Manual


 
MATERIAL USAGE INFORMATION
Pressing the VIEW key followed by the * key will cause all material
usage totals to be printed. The (*54) flag need not be on. These
totals are since the last time printed, and since the last time
cleared.
This same information may be periodically, and automatically, printed
by setting the PRT parameter to a time interval number. (See
PARAMETER, PRT)
The printout looks like this:
DATE TIME
CURRENT 6/20/91 13:40:14
LAST PRINTED 6/20/91 13:35:11
LAST CLEARED 6/19/91 20:02:36
TOTALS: GRAND PCT CURRENT PCT
CYCLES 11 7
COMP 1 R 05.0 2.4 4.8 1.5 5.0
COMP 2 N 100 47.4 100.0 28.6 100.0
COMP 5 N 00.5 .4 .99 .2 .99
COMP 6 N 00.5 .4 .94 .2 .91
TOTAL 50.8 30.7
WEIGH SCALE ID# 120
TOTALS ARE IN POUNDS
POUNDS PER HOUR 365.3
The Totals may be in POUNDS or KILOS depending on your selection of
weight unit. See: PROGRAM mode, (*89).
A line is printed for each active component. Each line shows component
number, type, setting, grand and current totals.
The GRAND totals will continue to grow until they are intentionally
cleared. This is done by the *00 routine, or pressing 00 within 5
seconds after printing these totals.
The CURRENT totals are since the last time totals were printed. The
date and times are given for LAST CLEARED and for LAST PRINTED.
The percentages given for "R" types (REGRIND) are percentages of the
total mix. Percentages given for "A" types (ADDITIVES) are percentages
of all the "N" types added together. Percentages given for "N" types
(NATURALS) are each component's percentage of all the "N" types added
together.
The POUNDS PER HOUR is calculated using the total material dispensed
from the CURRENT column, and the time difference between the CURRENT
time and the LAST PRINTED time. Cycle time variations will cause this
number to not be exact. The longer the time period, the more correct
the rate.
Page 81