Dacor DO230 Double Oven User Manual


 
PLANNING
GUIDE
www.Dacor.com Phone: (800) 793-0093
Specications subject to change without notice.
Install all appliances according to accompanying installation instructions.
1.11
DO
Double, Distinctive
Wall Oven
(A) Overall
Width
(B) Chassis
Width
(C) Overall
Height
(D)* Chassis
Height
(E) Control
Panel
Overlay
29 3/4”
(75.6 cm)
28 3/8”
(72.1 cm)
49 15/16”
(126.8 cm)
49 1/16”
(124.6 cm)
15/16”
(2.4 cm)
* To top of chassis notch behind control panel
(F) Utility
Cutout Width
(G) Utility
Cutout Height
(H) Utility
Cutout Depth
(J) Control
Panel Depth
(K) Notch
Depth
(L) Chassis
Depth
(M) Notch
Height
5”
(12.7 cm)
5 ¼”
(13.3 cm)
6”
(15.2 cm)
1”
(2.5 cm)
1 5/8”
(4.1 cm)
24”
(61.0 cm)
1”
(2.5 cm)
21 1/8”
(53.7 cm)
ELECTRICAL SPECIFICATIONS
Dedicated Circuit
Requirements
Total Connected Load
240 Vac 60 Hz.,
4-wire,** 40 Amp.
7.8 kW (33 Amp.)
** Two 120 Vac hot (L1 and L2), one neutral, one ground.
The above specifications are for reference only. See the
appliance data plate for exact specifications.
C
J
B
H
G
F
A
K
L
M
E
Chassis Notch
Side View
Control panel
front
Top of
chassis
Top of
chassis
Utility
cutout
Conduit:
60” (152 cm)
Long
D
Product tolerances: ±1/16” (±1.6 mm) unless otherwise stated
MODEL DO230
Document # PG01-008 Revised 05/25/10 Page 1/2
WARNING
Observe all governing codes and ordinances during planning •
and installation. Contact your local building department for
further information.
This appliance must be installed in accordance with the •
accompanying installation instructions.