Dacor ESG486LP Ventilation Hood User Manual


 
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
4.1
36”, 48” Wide,
Epicure™ Gas Cooktops
ESG366, ESG486
1/2
CABINET DIMENSIONS
Model No.
Electrical
Circuit
Required
Total
Connected
Load Gas Type
Manifold
Pressure
Min. Gas
Supply
pressure
Approximate
Shipping
Weight
ESG366
120 Vac,
60 Hz,15 Amp
0.25 Amps
(0.03 Kw)
Natural
4” Water
Column
5” Water
Column
128 lbs.
ESG366LP Liquid
Propane
10” Water
Column
11” Water
Column
ESG486
Natural
4” Water
Column
5” Water
Column
149 lbs.
ESG486LP Liquid
Propane
10” Water
Column
11” Water
Column
Gas and Electrical Requirements
NOTES:
1. If cabinet storage space is to
be provided directly above the
cooktop, the risk of personal injury
may be reduced by installing a
ventilating hood that projects
horizontally a minimum of 5 inches
(127mm) beyond the face of the
cabinets.
2. Access to the underside of the
cooktop, the electrical connection,
the gas shut-off valve and the
pressure regulator must be
provided for inspection and
service.
Plan the installation so that the electrical
connection, gas shut-off valve, and pressure
regulator are accessible from the front of the
cabinet, and that all of the minimum dimensions
are provided. Dimensions apply to all models
unless otherwise noted. Locate the electrical
supply box within reach of the included 48 inch
(1219mm) long flexible cord so the connection
is accessible when the cooktop is in place.
Hood
ESG366: 42" (1067mm) Recommended
36" (914mm) Minimum
ESG486: 54" (1372mm) Recommended
48" (1219mm) Minimum
10" (254mm)
Min. to
combustible side
wall, both sides
See Page 4
1 1/2" (38mm)
Typical Countertop
18"
(457mm)
30" (762mm)
Minimum
36"
(914mm)
28 1/4"
(717mm)
7 3/4"
(197mm)
Utilities
Location
C
L
6"
(152mm)
ESG366:
24" (610mm)
ESG486: 30" (762mm)
10"
(254mm)
15 1/2"
(393mm)
See Page 4
NOTES:
1. Factory installed liquid propane (LP) special
ordered.
2. Cooktop is supplied with a 48” (1219mm) power
cord, with a three prong grounded plug.
3. Utilities are located in the right rear corner of the
cooktop.
4. Utlities may be located in the right rear corner of
the cabinet below the cooktop. (Recommended)
5. See the Combination Installation (CI) Section if
installing with a downdraft, or warming oven.
Revised
02/29/08