Dacor MMD30S Microwave Oven User Manual


 
MMD24, MMD30 & MMDV30
1/1
Model No. Dedicated Circuit Required Total Connected Load
Approximate
Shipping Weight
All Models
120 Vac, 60 Hz, 15 Amp
(Breaker)
1.56 kW (13 Amp) 128 lbs.
4"
5"
electrical outlet location
2x4 Anti-
Tip block
(6")
ELECTRICAL UTILITY LOCATION
4"
5"
electrical outlet location
Anti-Tip
block
(6")
ANTI-TIP BLOCK LOCATION
24”, 30” Microwave In-A-Drawer
CUTOUT DIMENsIONs
Revised
08/27/08
NOTES:
1. All tolerances: +1/16”, -0, (+1.6mm, -0), unless
otherwise stated.
2. Spacing between appliances and doors/drawers
is minimum required to allow for ventilation and
to prevent scraping. Additional space may be
required for appearance.
ELECTRICAL sPECIfICATIONs
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
12.7
OVERALL DIMENsIONs
A. 6 "
B. Electrical outlet location
C. Anti-Tip block
D. 5"
E. 3 1/2"
F. 4"
G. 22 1/4" opening
H. 14 3/16" to bottom of Anti-Tip
block
I. Allow 7/8" minimum overlap
J. 23 1/2" minimum depth
K. Allow 3/16" minimum overlap
L. 36" nominal countertop height
M. Allow 7/16" minimum overlap
N. Floor must support 100 lbs.
minimum
O. 19" to top of oor (recommended)
P. 24" cabinet minimum
Q. 15 3/16" ± 1/16" opening
A
B
C
D
E
F
G
H
I
I
J
K
L
M
N
O
P
Q
G
48" (1219mm)
3-prong
120 Vac power cord
A
B
C
F
I
D
H
E
NOTE: Open Top Cabinet illustrated
MMD24
A. 6 "
B. Electrical outlet location
C. Anti-Tip block
D. 5"
E. 3 1/2"
F. 4"
G. 28 1/2" opening
H. 14 3/4" to bottom of Anti-Tip
block
I. Allow 3/4" minimum overlap
J. 23 1/2" minimum depth
K. Allow 1/4" minimum overlap
L. 36" nominal countertop height
M. Allow 7/16" minimum overlap
N. Floor must support 100 lbs.
minimum
O. 19" to top of oor (recommended)
P. 30" cabinet minimum
Q. 15 3/16" ± 1/16" opening
MMD30, MMDV30
A. 21 19/32"
B. 4 11/16"
C. 1 23/32"
G. 15 1/16"
H. 1" door thickness
I. 15" auto drawer opening
D. 23 3/8"
E. 23 13/16"
F. 15 5/8"
Power cord length: 48”
MMD30, MMDV30
A. 28 5/16"
B. 4 11/16"
C. 2"
G. 15 1/16"
H. 1 1/4" door thickness
I. 15 1/4" auto drawer opening
D. 23 3/8"
E. 30"
F. 15 5/8"
MMD24
A. 6 "
B. Electrical outlet location
C. Anti-Tip block
D. 5"
E. 3 1/2"
F. 4"
G. 22 1/4" opening
H. 14 3/16" to bottom of Anti-Tip
block
I. Allow 7/8" minimum overlap
J. 23 1/2" minimum depth
K. Allow 3/16" minimum overlap
L. 36" nominal countertop height
M. Allow 7/16" minimum overlap
N. Floor must support 100 lbs.
minimum
O. 19" to top of oor (recommended)
P. 24" cabinet minimum
Q. 15 3/16" ± 1/16" opening
A
B
C
D
E
F
G
H
I
I
J
K
L
M
N
O
P
Q
G
48" (1219mm)
3-prong
120 Vac power cord
A
B
C
F
I
D
H
E
NOTE: Open Top Cabinet illustrated
MMD24
A. 6 "
B. Electrical outlet location
C. Anti-Tip block
D. 5"
E. 3 1/2"
F. 4"
G. 28 1/2" opening
H. 14 3/4" to bottom of Anti-Tip
block
I. Allow 3/4" minimum overlap
J. 23 1/2" minimum depth
K. Allow 1/4" minimum overlap
L. 36" nominal countertop height
M. Allow 7/16" minimum overlap
N. Floor must support 100 lbs.
minimum
O. 19" to top of oor (recommended)
P. 30" cabinet minimum
Q. 15 3/16" ± 1/16" opening
MMD30, MMDV30
A. 21 19/32"
B. 4 11/16"
C. 1 23/32"
G. 15 1/16"
H. 1" door thickness
I. 15" auto drawer opening
D. 23 3/8"
E. 23 13/16"
F. 15 5/8"
Power cord length: 48”
MMD30, MMDV30
A. 28 5/16"
B. 4 11/16"
C. 2"
G. 15 1/16"
H. 1 1/4" door thickness
I. 15 1/4" auto drawer opening
D. 23 3/8"
E. 30"
F. 15 5/8"
MMD24