Delfield SSF-G Freezer User Manual


 
Project __________________________________
Item ____________________________________
Quantity ________________________________
CSI Section 11400
Approved _______________________________
Date ____________________________________
980 S. Isabella Rd.
Mt. Pleasant, Michigan 48858
Phone: 800-733-8948 or 989-773-7981
Fax: 800-669-0619
www.delfield.com
Delfield
®
Exterior: SS and SA models shall have corrosion resistant stainless steel
exterior cabinet sides, front and shroud. SM models shall have corrosion
resistant aluminum on exterior cabinet sides and will have stainless front
and shroud. All units shall have the upper shroud hinged with a gas assist
stay open feature to provide easy access to the refrigeration system.
Interior: Cabinet interior shall be corrosion resistant stainless steel (SS
models) or heavy gauge aluminum (SA and SM models). Bottom and top
surfaces shall be die stamped to provide radius corners and recessed oor.
Three wire shelves are provided per section, SA/SS standard shelves are
chrome plated, SM standard shelves are epoxy coated. Shelves rest on clips
which are adjustable on 1” increments on stainless steel pilasters axed
to the cabinet interior. Pilasters are removable without tools for cleaning.
Mounted to the interior ceiling, the interior uorescent light is controlled
automatically through a switch mounted in the hinge assembly to protect
against breakage. Door openings are protected with heavy gauge stainless
steel breaker strips. An air duct shall be mounted to the ceiling assuring low
velocity, even air movement throughout the cabinet interior.
Doors: Double paned tempered thermopane glass. Constructed with
a combination of extruded aluminum and PVC. Each door has two
edgemount, self-closing, cam lift style hinges. Doors can be removed from
the cabinet without the use of tools. Door handle is continuous along
vertical dimension of the door. Door gaskets are magnetic and mount to
the door, snapping in place and removable with out tools. Keyed door lock
is mounted to the door. Lock engages into a heavy duty strike mounted to
the cabinet face.
Refrigeration system: All components are mounted to the exterior of the
cabinet ceiling, outside the food zone and are assembled as one piece and
can be removed as one piece. Environmentally friendly R404A refrigerant
is used. The system has the capability of maintaining between -5ºF and
0ºF in heavy use food service operations. Refrigerant is metered using
a highly responsive thermostatic expansion valve. System is controlled
using Deleld’s ACT-Advanced Control Technology electronic temperature
control, which provides improved pull down times, reduces compressor
cycling and longer compressor life with lower energy consumption.
Control system uses adaptive defrost to assure evaporator coil is free
of ice and is operating at optimum eciency. Evaporator condensate is
eliminated using an energy ecient hot gas system.
Electrical: Standard electrical on one section units shall be 115V, 60 Hz
single phase. A 10’ cord and plug is supplied and attached to a junction box
mounted on the exterior top of the cabinet. Two and three section units
shall be 115/208-230 and will require hardwire connections.
Specifications
Standard Features
Options &
Accessories
Stainless steel interior and exterior (SS)
Stainless steel exterior, aluminum interior (SA)
Aluminum interior and exterior, stainless front
(SM)
Built in door locks with heavy duty strikes
Pressure relief valve is standard to prevent door
vapor lock
Exterior digital thermometer with high/low
temperature alarm
Easy to use electronic control
Easy access “ip up” shroud
Three wire shelves per section - SA/SS standard
with chrome plated shelves and SM standard
with epoxy coated shelves
10’ attached cord and plug on 115V units
6” adjustable stainless steel legs
Stainless steel breaker strips
High density foamed in place environmentally
friendly, Kyoto Protocol Compliant, Non ODP
(Ozone Depletion Potential), Non GWP (Global
Warming Potential) polyurethane keeps energy
costs low
Energy savings door heater switch
Two year parts & labor warranty
Five year compressor warranty
One section Two section Three section
SSF1-G SSF2-G SSF3-G Stainless exterior and interior glass full door
SSF1-GH SSF2-GH SSF3-GH Stainless exterior and interior glass half door
SAF1-G SAF2-G SAF3-G Stainless exterior and aluminum interior glass full door
SAF1-GH SAF2-GH SAF3-GH Stainless exterior and aluminum interior glass half door
SMF1-G SMF2-G SMF3-G Stainless front aluminum exterior and interior glass full door
SMF1-GH SMF2-GH SMF3-GH Stainless front aluminum exterior and interior glass half door
Models
Specication Line®
Self-Contained Glass Door Reach-In Freezer
Specication Line®: Glass Door Reach-In Freezer
Security (prison) package
6” polyurethane casters
Incandescent light
Door eld rehingability
Additional shelves
Tray slides
Stainless steel back
Laminate on front, sides and back
Bottom mount electrical
Stainless steel banking strip
Heat shield end
Stainless steel kick plate
Laminate kick plate
4” stainless steel utility base
230-50-1 electrical
220-60-1 electrical
SSF2-G