Ei Electronics Ei141 Smoke Alarm User Manual


 
Shannon Free Zone, Shannon, Co. Clare, Ireland.
Ph.+353 61 471277 Fx.+353 61 471053
Email. eielectronics@eiltd.ie
Web: www.eielectronics.com
E & OE As our policy is one of continuous product development, we reserve the right to alter product details without prior notice. Ei141 DataSht RevB
Model Ei141 Ionisation
Easi-Fit base
9V Alkaline Battery back up
High performance ionisation chamber
Test/Hush button
Advanced suppression and calibration technology
Interconnectable to other Ei mains powered alarms
Low power cell warning
Kitemarked to BS EN 14604:2005
5 year guarantee
Product Description
The Ei141 is an Ionisation Smoke Alarm that runs on
230V AC mains power, and has a 9V alkaline battery
back up in the event of mains failure. The 9V battery will
last for up to 4 years in standby mode, and capable of
powering the smoke detector for up to 2 years in the
event of mains failure.
The Ei141 is supplied with the Easi-Fit base that allows
very quick and simple installation of the smoke alarm,
combined with simple detector head removal and
replacement. The Easi-Fit base automatically connects
both mains power and battery as the detector head
slides on to the Easi-Fit base.
The Ei141 has other advanced features such as the
ability to interconnect up to twelve alarms to allow all
alarms to sound if just one of the interconnected alarms
should be triggered.
The Ei141 has built in circuitry to aid suppression of
voltage transients and RF interference to further reduce
the chances of false alarms under such conditions.
Operation
The green indicator will illuminate to show mains
power is present
The red indicator will flash rapidly to show an alarm
condition for the smoke detector
The “Test/Hush” button will either silence false
alarms or perform a unit self test
In “Test” mode the alarm will perform a self test and
sound the horn
In “Hush” mode the alarm enters a ten minute period
of reduced sensitivity to overcome false alarm
conditions, and will then automatically reset itself
When interconnected to other Ei mains powered
alarms, an alarm on one detector will trigger all other
interconnected alarms within one second (only the
triggered alarm will flash a red indicator)
The smoke detector will emit a beep every 40
seconds to indicate that the battery back up is
depleted and needs recharging
MAINS POWERED 230V~
9V Alkaline Battery Back-Up