Electrolux EI36WC40GS Ventilation Hood User Manual


 
1515
1515
15
Special functions
Clock prClock pr
Clock prClock pr
Clock pr
ogrammingogramming
ogrammingogramming
ogramming
The clock can be reprogrammed at any time except during an active timed function.
The clock can be displayed in a twelve hour format and valid clock times are from 1:00 to 12:59.
The clock can be reprogrammed pressing the “
TT
TT
T
imerimer
imerimer
imer” button for 5 seconds, and after, the clock can be
adjusted with the “
” and “ ” buttons. Colon “:” will flash indicating clock programming mode.
The user can have minute increments / decrements of 1 minute, but if the user keep pressing the “
”/
” buttons for more than 1 second, the increments / decrements will be of 5 minutes.
During this option the control will round to the nearest 5 minutes.
The user can finish on reprogramming the clock pressing the “
TT
TT
T
imerimer
imerimer
imer” button.
After 1 minute of no button pressed the control will accept the programmed clock time and will add one
minute to the set clock.
GrGr
GrGr
Gr
ease filter saturation alarmease filter saturation alarm
ease filter saturation alarmease filter saturation alarm
ease filter saturation alarm
After thirty fan functional hours, the display will show “
GrGr
GrGr
Gr
ease Filterease Filter
ease Filterease Filter
ease Filter” if the fan is active.
When this icon is shown in the display, the grease filters installed are required to be washed.
To reset the grease filter saturation alarm the user must press the “ ” button for 5 seconds, after this
action the icon “
GrGr
GrGr
Gr
ease filterease filter
ease filterease filter
ease filter” is not displayed, and the hood has the normal display operation.
CharChar
CharChar
Char
coal filter saturation alarm (Recircoal filter saturation alarm (Recir
coal filter saturation alarm (Recircoal filter saturation alarm (Recir
coal filter saturation alarm (Recir
culating accessories)culating accessories)
culating accessories)culating accessories)
culating accessories)
After one hundred and twenty functional hours of the fan, the display will show “
CharChar
CharChar
Char
coal Filtercoal Filter
coal Filtercoal Filter
coal Filter” if the fan
is active. When this icon flashes on display, the charcoal filters installed are required to be replaced or
reactivated.
To reset the charcoal filter saturation indication the user must press the “ ” button for 5 seconds, after
this time the icon “
CharChar
CharChar
Char
coal filtercoal filter
coal filtercoal filter
coal filter” is not displayed and the hood has the normal display operation.
Audible signal activation and deactivationAudible signal activation and deactivation
Audible signal activation and deactivationAudible signal activation and deactivation
Audible signal activation and deactivation
The audible signals can be activated or deactivated pressing the “
LightLight
LightLight
Light” button for 5 seconds.
If the audible signal is activated, a tone must sound and the “
SndSnd
SndSnd
Snd” symbol must appear on the display for
2 seconds.
If the audible signal is deactivated, the “
SndSnd
SndSnd
Snd” symbol must appear on the display for 2 seconds and no
tone must sound.
CharChar
CharChar
Char
coal filter inclusion and exclusion (Recircoal filter inclusion and exclusion (Recir
coal filter inclusion and exclusion (Recircoal filter inclusion and exclusion (Recir
coal filter inclusion and exclusion (Recir
culating accessories)culating accessories)
culating accessories)culating accessories)
culating accessories)
The charcoal filter inclusion or exclusion can be set by pressing the “ ” and “ ” buttons at the same
time for 5 seconds.
The Inclusion or exclusion of charcoal filter must be selected while the lamps and the motor are OFF.
When the charcoal filter has been excluded, the charcoal filter alarm is disabled.
Heat sensorHeat sensor
Heat sensorHeat sensor
Heat sensor
The control is equipped with a heat sensor that will turn on the blower at second speed if excessive heat
occurs (over
158° F158° F
158° F158° F
158° F or
70°C70°C
70°C70°C
70°C) surrounding the control area.
If the blower is OFF or if it is operating at first speed, the blower will be set automatically to second speed,
the display shows the word "
CArECArE
CArECArE
CArE" to indicate that heat sensor has detected an excessive heat.
During this state, the user may raise the blower speed to third speed but can not decrease the speed.
When the temperature level on the hood drops to normal, the blower will operate in the setting defined by
the user before the alarm occured.
Control buttons - Special functions