Elmira Stove Works 1860 Range User Manual


 
C
OMBINATION
RANGES
A
LL GAS
RANGES
E
LECTRIC
WALL
OVENS
E
LECTRIC
RANGES
U
PPER CABINET
POWER RATING
OVENS
RANGE DIMENSIONS
Four Burner Model: 30 1/8" W x 67 7/8" H x 29 1/2" D. Six Burner
Model: 44 1/4" W x 67 7/8" H x 29 1/2" D. Our 30" models will fit into a
30 1/4" opening without cabinet alterations. Short leg models require a
minimum opening of 30 3/4", and are 65 7/8" high.
R
ANGETOPS
RANGES
FEATURES & SPECIFICATIONS
1850 1855 1865 1870 1875 1860 1867 1880
Range Widths *30 1⁄8" 44 1⁄4" 44 1⁄4" *30 1⁄8" 44 1⁄4" *30 1⁄8" 44 1⁄4" 29 7⁄8"
Self-Cleaning Electric Oven (4.3 cu. ft.) •••••
Oven Size: 25" W x 16" H x 18 3⁄4" D
Electric Self-Cleaning Convection Oven (4.0 cu. ft.) optional optional optional optional optional
Oven Size: 25" W x 16" H x 16 5⁄18" D standard on STE Models
Gas Self-Cleaning Oven with waist high Broiler (4.0 cu. ft.) ••
Oven Size: 25" W x 16" H x 18" D
“Stay Hot” Food Warmer •••
Electronic Oven Control ••••••••
Delayed Start Baking ••••••••
Dual Element Baking •••••
Vari. Temp. Broil ••••••••
Door Activated Oven Light ••••••••
Heavy Duty, Plated Oven Racks ••••••••
Porcelain Enamel Broiler Pan ••••••••
Electric High–speed Radiant Elements under glass (ST) optional optional
High–Speed Radiant Elements
under glass with Electronic Control (STE) optional optional
Gas: Sealed Surface Burners with cast grates 4••••
Converts to L.P. (Propane) •••••
Gas Top Burners, 8,000* BTU 22323
Gas Top Burners, 12,000* BTU 11212
Superburner, 15,000* BTU 11111
*Ratings for liquid propane are approximately 10% lower
Ultra Temp™ Electric Cast Elements optional optional
Electric High Speed Radiant Elements under glass optional
Porcelain Enamel Work Surface (replaces two burners/elements) optional optional
Electronic Spark with Re–ignition •••••
Easy Clean Porcelain Top or Top Frame •••••••
Nickel Trimmed Range Top •••••••
350 CFM Exhaust Fan standard (recirclating and outside vent) •••••••
636 CFM In-line Exhaust blower (outside vent only) optional optional optional optional optional optional optional
Cooking Surface Light, Night Light •••••••
“Feather Touch” Tempered Glass Oven Control Panel •••••••
Power Source (208 to 250V) appliance rating 220V-35A 220V-50A 220V-30A 220V-20A 220V-20A 120V-5A 120V-6A 220V-30A
Power Ratings NG (BTU’s) 43,000 43,000 63,000 58,000 78,000
Power Ratings LP (BTU’s) 38,700 38,700 56,700 52,200 70,200
Power ratings/oven burner NG (BTU’s) 16,000 16,000
Shipping Weight 375 lbs. 410 lbs. 420 lbs. 385 lbs. 425 lbs. 395 lbs. 435 lbs. 200 lbs.
NATURAL GAS OR PROPANE?
Ranges are built to accommodate natural gas unlesspropane(LP)has beenspecified on yourorder.Conversionpartsareavailableand areeasy toinstall.(See productmanualfor instructions.)
IMPORTANT
FittingRangeintoCabinetOpening: FourBurnerModels:Ifyou aredesigning
cabinets tofit range, leave33"betweenbasecabinets. Countertopover-
hangs oneachside shouldbe1-3/8".Rangeswillfitopeningsassmall as
30-1/4".Shortleg models require31"minimumclearancebetween counter-
tops. SixBurnerModels:Require 45-1/2"openingbetweenbasecabinets.
Leftcountertopoverhangshouldbe1-3/8".Nooverhangrequired onright
side.Countertopsshouldbestandard 36"high.
*Will fit minimum30 1/4"cabinetopening.
STANDARD EXHAUST FAN
The standard350c.f.m.exhaust fan, includedinthe uppercabinet ofyourrange,isfactory-set torecirculateairthrougha charcoal
filter.Itcanalsobeusedtooutside-ventexhaustifthereisnot morethanone90degreeelbowormorethan ten feetbetweenthe
rangeand theoutside wall.Thisfanexhaustsaironly fromthe back ofthe range cabinet– itcannotbeadaptedfor top-venting.
EXHAUST OUTLET LOCATION
Height from floor to center of duct openingis62 5/8". From leftbase cabinet countertopoverhangtocenterof duct openingis
14". Ifinstallinga fourburnerrangeinto a301/4" opening, dimension shouldbe 85/8". Heightfrom floor to center of duct
openingis 60 5/8"for shortlegmodels.
#1518 OPTIONAL IN-LINE EXHAUST BLOWER
The optionalin-lineexhaust blower replacesthestandard 350 c.f.m.exhaust fanprovided in your rangecabinet, andis tobe in-
stalled by your contractor where yourexhaust ducting exits the house. The inlineblower shouldbe ordered whenyoupurchase
your range -therangeandwiring must bemodified to accommodate the blower. (The blower canbe shipped inadvance ofthe
range for installation –additionalshippingchargeswillapply.)
Ifyouare outside-venting yourrangewith morethan 10 feetof ducting, or more thanoneelbow or if yousimply prefera more
powerfulexhaust system …youshouldinclude theoptional 636c.f.m. in-lineexhaustblower. The#1518In-LineBlower exhausts
smoke andcookingodorsquickly andquietly,exitingthe houseupto 35feet fromthe range. Ifdesired, theblowercanbemounted
inthebasementorattic forpowerful,whisper-quietoperation.
Theblower can be mounted vertically, horizontally oratanyangle.
Backward-curved airfoilblades move maximumairwith minimal sound.
Fan and motor are precisionbalancedforquietvibration-freeoperation.
Blowerwiring attaches tothejunctionbox on the backof yourrange.
SPECIFICATIONS:
636cubic feet/ minute • 210 Watts,115 Volts, 1.85 Amps, 60 Hz •Blowerlength:9-1/8"
•Blowerdiameter:13-1/2" (electricalbox protrudes1-3/4"DX 4-1/2"Wfromsideofblower)• Inlet/ outlet:8"
•Warranty: Oneyear
IN-LINE EXHAUST BLOWER KIT CONTAINS:
Exhaust blowerwith 8" inletandoutlet
Adapterelbow –attaches to backof range, converts range outletto3-1/4"X 10" standard duct size.
Ductadapter– converts 3-1/4"X 10" duct to8" round duct
Backdraftdamperwith spring return –prevents coldairfrom enteringhouse whenblower is notin use.
Outside louver grill – covers the exhaust outlet at soffit or foundation wall.
Louvers automatically close when the blower is not in use.
Ductextender– mounts to backof range cabinet, replacingdeflector plate.
Ductpipe, roofflashingandroofcap(ifrequired) are not included.
WARRANTY
One-year warranty, coveringparts andlabor.Additionalfour-yearwarranty(five years total)parts only on range /wall oven
burners andelements, fridgesealed refrigeration unitandcompressor, andmicrowave magnetron tube.
NOTE
The January98electricalstandard requires that afour wirerangecordbeusedinall newconstruction. Pleaseadviseifathreewire
rangecord isrequired(usedonly inexistingconstruction). Theelectricalreceptacleand gas pipingshouldbeinstalledapproxi-
mately4”above thefloorand15” totherightofthe left edgeofthe cabinetopening(as youarefacingtheopening).
All 220V ranges come with standard four wire range cords attached.
ALL DIMENSIONS ARE FOR PLANNING PURPOSES ONLY
Specifications are subject to change without notice. We reserve the right to make product changes as required,
without notice. Consultinstallation instructions before cutting cabinets, counter tops or exhaust outlet.
SAFETY & EFFICIENCY
Elmira StoveWorks appliancesmeetor exceed the most stringent U.S. and Canadian safety and efficiencystandards.
Attic In-Line Exhaust Blower Installation
The in-line blower and ducting can be mounted to or between (allowing for
14" blower diameter) structural joists. Alternate installation: The exhaust
duct can extend straight up through the roof (similar to Installation #3). This
method will require a roof flashing and cap, not included.
Basement In-Line Exhaust Blower Installation
The exhaust duct runs down the wall behind the range into the basement,
where it exits through the foundation wall. The in-line blower and ducting
can be mounted to or between (allowing for 14" blower diameter) structural
joists.
Roof In-Line Exhaust Blower Installation
(straight up from cabinet)
Log homes and homes with a cathedral ceiling often require a top-ducted
exhaust. Advise your dealer if you are using this application a 7" round
hole must be made in the top center of your range cabinet. We highly recom-
mend locating your range in the kitchen prior to cutting the hole in the roof.
(Ducting can also be routed through kitchen cabinets above the range, if de-
sired.) 7" duct pipe, 7" to 8" increaser, roof cap and roof flashing are not in-
cluded.
Antique_Range_Specs:Layout 1 5/22/08 2:29 PM Page 1