Enviro 50-1235 Ventilation Hood User Manual


 
Horizontal Vent Kit
50-1235
KIT COMPONENTS:
Quantity Description Quantity Description
1 Horizontal direct vent termination cap 4 Wire spacers
1 Flue collar adapter 1 4 oz tube Mill-Pac Sealant
1 Wall thimble 1 4 oz tube RTV silicone
1 5’ (190 cm) length of Ø4” (10 cm) double walled ex pipe 12
9
/16” tech screws
1 5’ (190 cm) length of Ø6” (10 cm) double walled ex pipe 8 1½” wood screws
Please ensure that all components are supplied with this kit. If components are missing or have been damaged,
contact your dealer, distributor, or courier company. Do not attempt the installation if components are missing
or damaged.
INSTALLATION INSTRUCTIONS:
Figure 1
Please read and understand these instructions before installing. Failure to follow these
instructions carefully could cause property damage or personal injury.
For use with Haven & Retreat Direct Vent replaces.
10"
(254mm)
10"
(254mm)
Wire
spacers
Figure 2
1. Plan your installation and clearances to combustibles. Decide on a location
for the unit that will meet any or all local code requirements. Refer to the
sections in your owner’s manual on where to locate your stove.
2. Set the appliance in the desired location. Determine if any wall studs,
electrical wiring, or plumbing pipes are in the way of the venting system
as it passes through the exterior wall. The replace location should be
adjusted if obstructions are found in the wall.
3. Project a line from the center point of the ue
outlet upward and outward to the desired ue
outlet location on the exterior wall. Using this
center point, scribe a 10” (25.4 cm) hole or
square on the wall. Cut the hole out on both
the interior and exterior wall surfaces.
4. Frame the hole as shown in Figure 1.
5. Trim the Wall Thimble to match the wall thickness as necessary. Install the wall
thimble and secure it to the inner wall frame using four (4) 1½” wood screws.
6. Apply a bead of Mill-Pac Black sealant to the new Ø4” (10 cm) by 5” (12.5 cm)
provided ue collar adaptor. Press the ue collar into the ue outlet of the
replace so that the Mill-Pac seals the ue collar to the ue outlet.
7. Stretch both the Ø4” (10 cm) ex vent and the Ø6” (16.25 cm) ex intake
liner to the length needed to ensure the ex can be easily connected to the vent
terminal.
8. Slide the Ø6” (16.25 cm) ex intake liner over the ex vent. Install four (4)
wire spacers around the ex pipe. Ensure the wire spacers are positioned at
either end of the pipes, and at each end of any elbows in the liners (refer to
Figure 2 and 3).