PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
VENTING REQUIREMENTS
TMH16XS
Electrical: A 120-volt, 60 Hz, AC-only, 15 or 20
amp electrical supply located in the upper cabinet
as close as possible to the microwave oven hood.
A time-delay fuse or circuit breaker and separate
circuit is recommended.
®
Microwave Hood Combination
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 8206587
09-19-06
Recommended standard fittings
If the existing vent is round, a rectangular-
to-round adapter must be used and a
rectangular 3" (7.6 cm) extension vent
between the damper assembly and the
adapter must be installed to prevent sticking
of the exhaust damper.
1 - 3-1/4" x 10"
90° elbow = 25 ft. (7.6 m)
1 - wall cap = 40 ft. (12.2 m)
8 feet straight = 8 ft. (2.4 m)
Length of
3-1/4" x 10" system = 73 ft. (22.2 m)
6" (15.2 cm) vent system
3-1/4" x 10" (9.5 cm x 25.4 cm) vent system
1 - transition = 5 ft. (1.5 m)
2 - 90° elbows = 20 ft. (6.1 m)
1 - wall cap = 40 ft. (12.2 m)
8 feet straight = 8 ft. (2.4 m)
Length of 6" system = 73 ft. (22.2 m)
3-1/4" x 10"
90° elbow
90° elbows
transition
wall cap
6 ft. (1.8 m)
2 ft. (0.6 m)
3-1/4" x 10"
to 6" = 5 ft.
3-1/4" x 10"
roof cap = 24 ft.
3-1/4" x 10"
90° elbow = 25 ft.
90° elbow
6" = 10 ft.
3-1/4" x 10"
wall cap =
40 ft.
3-1/4" x 10"
90° flat
elbow= 10 ft.
45° elbow
6" = 5 ft.
Recommended vent length
Use 3-1/4" x 10" (8.3 cm x 25.4 cm) rectangular or 6" (15.2 cm)
round vent. The total length of the vent system including
straight vent, elbow(s), transitions, wall or roof caps must not
exceed the equivalent of 140 feet (42.7 m) of 3-1/4" x 10"
(8.3 cm x 25.4 cm) rectangular or 6" (15.2 cm) round vent.
For best performance, use no more than three 90° elbows. To
calculate the length of system you need, add the equivalent feet
for each vent piece used in the system. See examples below.
NOTE: There must be at least one 2" x 4"
(50.8 cm x 101.6 cm) wall stud and
minimum 3/8" (9.5 mm) thickness
drywall or plaster/lath within cabinet
opening. Must be able to support
150 lbs. (68 kg).
* 30" (76.2 cm) is typical for
66" (167.6 cm) installation height.
Exact dimensions may vary
depending on type of
range/cooktop installed below.
Roof venting
Wall venting
roof cap
3-1/4" x 10"
(8.3 cm x 25.4 cm)
through-the-roof
3-1/4" x 10"
(8.3 cm x 25.4 cm)
through-the-wall
wall cap
CABINET OPENING DIMENSIONS
For wall or roof venting methods:
If the wall exhaust method is chosen, be sure that
there is proper clearance within the wall for the
damper to fully open.
Wall and roof caps must have back-draft damper.
We recommend:
✔ using rigid metal vent.
✔ that length of vent and number of elbows should
be kept to a minimum to provide efficient
performance.
✔ that size of vent should be uniform.
✔ using duct tape to seal all joints in the vent
system.
✔ using caulking compound to seal exterior wall or
roof opening around cap.
✔ two elbows should not be installed together.
We do NOT recommend:
✔ flexible metal vent.
NOTE: If flexible metal vent must be used, calculate
each foot of flexible metal vent as two feet of rigid
metal vent. Flexible metal elbows count twice as
much as standard elbows.
6 ft. (1.8 m)
2 ft. (0.6 m)
2
9
⁷
⁄
₈
"
(
7
6
.
0
c
m
)
1
5
³⁄₄
"
(
4
0
.
0
c
m
)
1
7
¹⁄
₄
"
(
4
3
.8
c
m
)
1
6
¹⁄
₄
"
(
4
1
.
3
c
m
)
66" (167.6 cm) min.
12" (30.5 cm) min.
14" (35.6 cm) max.
A B
30" (76.2 cm) typical*
30"
(76.2 cm)
min.
NOTE: The grounded 3 prong outlet must be inside the upper
cabinet. See “Electrical Requirements” section.
A.2" x 4" wall stud
B.Grounded 3 prong outlet
66" (167.6 cm)
min.