System Startup:
Water supply does not need to be turned off, however, do not use ice and water dispenser while installing filter.
The filter cartridge has already been installed in the filter housing at the factory. Refer to the
How The Water Dispenser
Works
section to properly fill the system with water.
Automatic Ice and Water Dispenser
Order new filter cartridges through the
dealer where you bought the refrigerator,
or contact the
Consumer Assistance
Center
at 1-800-944-9044. It might be
good to order some filter cartridges when
you first install your refrigerator. Be sure
to ask for
the
RG-100
PureSource ™
replacement cartridge.
Changing the Filter:
Water conditions vary throughout the world, but changing the water filter every
6 - 9 months normally will ensure the highest possible water quality. The Filter
Status light will turn red after 400 gallons of water has flowed through the ice and
water dispenser. Also, if the filter has been in a refrigerator that has not been in
use for awhile (during moving for example), change the filter before reinstalling
the refrigerator. The dispenser system will also operate without filtration (with
filter cartridge removed).
To change filter:
It is not necessary to turn the water supply off to change the filter.
1. Open freezer door and leave open until filter change is complete.
2. Set ice maker wire signal arm to the OFF (up) position (See illustration on
page 12).
3. Hold filter cup firmly, and unscrew towards left (Some water could
leak out as you remove cup. This is normal.). Filter cartridge should come
down with cup. If cartridge remains in housing, pull down gently, while
twisting filter back and forth.
4. Rinse out cup under running water.
5. The large o-ring that seals the filter system sets in the o-ring groove
down inside the cup. Should the o-ring fall out during filter cartridge
replacement, simply place it back in the groove prior to screwing the cup
back in place. If the o-ring becomes damaged, you will need to order one
from the
Consumer Assistance Center
.
6. Discard old filter cartridge.
7. Remove new filter cartridge from packaging and place in cup. The end
with the small o-ring should be up, out of the cup.
8. Screw cup, with filter, back onto housing. Do Not Use Wrench To Reinstall
Cup. Filter cartridge will self-align as cup is tightened. Be sure cup is
completely tightened with
PureSource ™
logo facing outward. Do Not
Tighten Past Stop.
9. Set ice maker wire signal arm to the ON (down) position.
10. Check for leaks. Open refrigerator door. Wipe any water droplets from the
filter cup. Fill a glass with water. If there is a leak, unscrew filter cup, and
reinsert the filter cartridge. Check placement of large O-ring. Reinstall
filter cup, making certain it is tightened completely.
11. To condition filter system and purge air from water line, fill a glass with
water. Continue flushing the system for 30 seconds to assure that the
purest water possible is stored in water tank.
IMPORTANT: Resetting The Filter Status Light (some models)
After replacing the filter cartridge, it will be necessary to press the
Filter
Status
reset button located on the ice and water dispenser. This will reset
the Filter Status light. Push the reset button until the green light flashes
(3-15 seconds). Please refer to the complete dispenser operating
instructions attached to the inside of the freezer door.
The
PureSource™
NGRG-
2000 Ice and Water Filter
System with the RG-100
cartridge is tested and
certified by NSF International,
the nationally recognized and respected,
not for profit, certification organization for
public health safety. The
PureSource™
system is tested and certified to ANSI/NSF
Standard 42. See performance data sheet
for specifications. This system should not
be used on water that is microbiologically
unsafe or with water of unknown quality
unless the water has been adequately
disinfected before or after traveling through
the filtration system.
• Rated Capacity - 400 gallons
• Rated service flow - .5 GPM
• Maximum Rated Pressure - 100 PSI
• Maximum Operating Temp. - 100° F