30" Dual-Fuel Professional Range with 4 Burners
Dimensions and Installation Information (in inches)
All Professional Ranges are factory set for natural or liquid
propane gas. The correct model should be ordered for the
installation situation.
Note: Conversion kits are included with the range if the wrong
gas type was ordered. High Altitude kit, WB28K10553 for
operation above 3,000 feet, is also available. The kits must be
installed by a qualified service technician at additional cost.
Installation Information
Before installing, consult installation instructions packed with
product or online at Monogram.com for current dimensional
data.
A 30" or 36" wide professional vent hood with a minimum 300
CFM is recommended for installation over this range. Install
the hood 30" to 36" above the cooking surface.
Advance Planning
Refer to dimensional drawings for appropriate placement
and necessary clearances when planning the installation.
• Working areas adjacent to the range should have 18"
minimum clearance between countertop and cabinet
bottom.
• Clearance between range and side wall or combustible
material must be at least 12" on each side.
• Installation must conform with local codes. In the absence
of local codes, the range must comply with the National
Fuel Gas Code, ANSI Z223.1-990.