GE ZSC1000/1001K Oven User Manual


 
ZSC1000/1001K
GE Monogram Built-In Advantium
®
120 Oven
For answers to your Monogram,
®
GE Profile
or
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
service,
800.626.2000.
R
Listed by
Underwriters
Laboratories
130315
Specification Created 4/05
Cutout and Product Dimensions
Advantium 120 Oven Installed Alone - Order a 27" or
30"- wide single oven cabinet or cut the opening in a
wall to the dimensions shown.
Advantium 120 Oven Installed Above a Monogram
Warming Drawer - An anti-tip block must be installed at
the rear of the warming drawer opening. See installation
instructions for complete details.
• The warming drawer must be supplied with a separate
120V, 60Hz, properly grounded receptacle.
Advantium 120 Oven Installed Above a Monogram
Single Wall Oven - When installed over a single oven
or a warming drawer, allow at least 2" between the two
openings. This separation will provide clearance for
bottom overlap of the Advantium oven and top overlap
of the single oven or warming drawer.
• The Advantium 120 oven and single oven combination
must be supplied with separate electrical connections.
Advantium 120 Oven Installed Above a Monogram
Single Wall Oven and a Warming Drawer - An anti-tip
block must be installed at the rear of the warming drawer
opening. See installation instructions for complete details.
• The warming drawer and the Advantium 120 oven must
be supplied with separate 120V, 60Hz, properly
grounded receptacles.
Electrical Location - Locate a recessed outlet within 6" of
either side and at least 9" above the cutout floor.
The serial plate is located on
the oven cavity flange,
behind the door.
Installed Above a Monogram Warming Drawer
* Note:
The middle rail
separating the
two openings
may need to
be larger than
the 2" min.
shown.
* Note:
The middle rail
separating the
two openings
may need to
be larger than
the 2" min.
shown.
* Note:
Additional clearance
between the cutouts
may be required.
Check to be sure
the oven supports
above the warming
drawer location do not
obstruct the required
interior depth and
height. See each
specific product’s
installation instructions
for details.
17-1/2"
36-3/4"
Min.
27" or 30"
25-1/8" Min.
25-1/4" Max.
26-3/4"
23-1/2"
18-5/8"
21-1/2"
29-3/4"
with side trim
18-5/8"
6"
9"
Locate Outlet Box in
the Shaded Area
Construct Base
Min. 3/8" Plywood
Supported by 2 x 4 or
1 x 2 Runners
all Four Sides
Dimensions and Installation Information (in inches)
Installed Above a Monogram Single Wall Oven
Installed Above a Monogram Single Wall Oven
and a Warming Drawer
36-3/4"
Min.
Construct Solid
Bottom Min.
3/8" Plywood
Supported by
2 x 4 or 1 x
2
Runners, all
Four Sides
2" Min.
Install 2 x 4
or 2 x
2
Runners or
Solid Bottom,
Must Support
100 lbs.
17-1/2"
9-1/4"
27" or 30"
23-1/2"
25-1/8" Min.
25-1/4" Max.
27" or 30"
23-1/2"
45-1/4"
Construct Solid
Bottom Min. 3/8"
Plywood
Supported by
2 x 4 or 1 x
2
Runners, all
Four Sides
2" Min.
Per Oven
Requirement
17-1/2"
25-1/8" Min.
25-1/4" Max.
27" or 30"
23-1/2"
17-1/2"
45-1/4"
Construct Solid
Bottom Min. 3/8"
Plywood
Supported by
2 x 4 or 1 x 2
Runners, all
Four Sides
2" Min.
Per Oven
Requirement
2" Min.
9-1/4"
25-1/8" Min.
25-1/4" Max.