Dimensions and Installation Information (in inches)
Installation Flexibility
These ovens may be installed in combination with a Monogram
warming drawer.
Note: Cabinets installed adjacent to wall ovens must have an
adhesion spec of at least a 194°F temperature rating.
Installation Information: Before installing, consult installation
instructions packed with product for current dimensional data.
For answers to your Monogram appliance
questions, visit our website at monogram.com
or call GE Answer Center
®
service,
800.626.2000.
Specification Revised 5/07
130187
ZEK958SM/BM
Monogram 27” Built-In Double Oven
KW Rating
240V 6.8
208V 5.1
Breaker Size
240V 40 Amps
208V 30 Amps
Listed by
Underwriters
Laboratories
13-1/4"
27"
23-1/2"
10"
49-11/16"
Min.
50-1/8"
Max.
Locate Electrical Outlet Within 10"
of Left Side of Opening and 44" Above
Cutout Floor or 5" Below Cutout Floor
605Dia93
25" Min.
25-1/4" Max.
51"
26-5/8"
23-1/4"
Recessed
Depth
13-1/4"
27"
23-1/2"
10"
49-11/16"
Min.
50-1/8"
Max.
Locate Electrical Outlet Within 10"
of Left Side of Opening and 44" Above
Cutout Floor or 5" Below Cutout Floor
605Dia93
25" Min.
25-1/4" Max.
51"
26-5/8"
23-1/4"
Recessed
Depth
The solid bottom or runners must be level with the bottom of the
cutout, or the bottom trim may not install correctly and could
interfere with the door opening. If the cabinet does not have a
solid bottom, two braces or runners must be installed level with
the bottom of the cutout to support the weight of the oven. The
runners and braces must support 300 lbs. (135 kg).
NOTE: Install the
oven only with
specific models
listed on the label
located on top of
the oven.
Anti-Tip Block
Against Rear
Wall Per
Warming
Drawer
Requirement
2 (5.1 cm)
Min.
1 (2.5 cm) Min. Above Toekick
Per Warming
Drawer
Requirement