GE Monogram ZIDI240WII Refrigerator User Manual


 
For answers to your Monogram,
®
GE Profile
or
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
service,
800.626.2000.
120032
Specification Created 12/07
Listed by
Underwriters
Laboratories
ZIDI240WII
GE Monogram
®
Double-Drawer Refrigerator Module
(Custom panel required)
ZIDS240WSS
GE Monogram Double-Drawer Refrigerator Module
(Stainless steel)
Dimensions and Installation Information (in inches)
Installation Space
The cutout depth must be 24"
• Both models can be installed flush with stardard cabinetry.
• Designed to be built-in only. Cannot be used free-standing.
• White case and drawer sides, black vented toekick with
optional stainless steel toekick supplied.
Additional Specifications:
• A 120 volt 60Hz., 15 or 20 amp power supply is required. An
individual property grounded branch circuit or circuit
breaker is recommended. Install a properly grounded 3-
prong electrical receptacle recessed into the back wall as
shown. Electrical must be located on rear wall as shown.
Note: GFI (ground fault interrupter) is not recommended.
34-1/2"-35"
24" Min.
23-3/4"
34-1/2"
23-3/4" Stainless Steel
Models
24-7/8" Framed Models
1-1/2"
Locate Outlet
9"
Max.
10-1/2"
Depth Including
Handle:
26" Stainless Steel
Models Only
23-3/4" Min.
Note: If installing between frameless
cabinets, a 1/2" wide filler strip or side panel
may be required. The filler strip will act as a
spacer between the door case and adjacent cabinet
and will prevent interference with cabinet door swing.
The width of the opening must include filler panels.
34-1/2" - 35"
24" Min.
47-1/2" Min.
1-1/2"
Locate Outlets
9"
Max.
10-1/2"
1-1/2"
9"
Max.
10-1/2"
24"
For a complete food storage center, install two Monogram
refrigeration modules side-by-side.
Note: Reversible door swing on wine chillers/reserves and
beverage centers only. See below for combination cutout
dimensions.
Important Note: Products must operate from separate,
properly grounded receptacles.
Note: Additional cutout width may be required for
models with custom panels.