Grease Grabber™ Power Play
Kitchen Exhaust Pollution Control System
Grease Grabber™ Power Play
The Greenheck Grease Grabber™ Power Play
is a pre-engineered electrostatic precipitator
type filtration pollution control unit with
integral exhaust fan (available without exhaust
fan as an option). The unit is designed to
remove grease and smoke particles as well
as odor molecules from the kitchen exhaust
airstream. This installation manual covers
procedures for receiving, installing, and
maintaining the filtered section of the unit.
For additional instructions and maintenance
information on the integral exhaust fan,
when applicable, refer to the fan nameplate
to determine model type and visit www.greenheck.com to
download the corresponding manual.
Only qualified personnel should install this system.
Personnel should have a clear understanding of these
instructions and should be aware of general safety
precautions. Improper installation can result in electric
shock, possible injury due to coming in contact with
moving parts, as well as other potential hazards.
Other considerations may be required if high winds
or seismic activity are present. If more information
is needed, contact a licensed professional engineer
before moving forward.
• Follow all local electrical and safety codes, as well
as the National Electrical Code (NEC), the National
Fire Protection Agency (NFPA), where applicable.
Follow the Canadian Electric Code (CEC) in
Canada.
• The rotation of the fan wheel is critical. It must
be free to rotate without striking or rubbing any
stationary objects.
• Fan motor must be securely and adequately
grounded.
• Do not spin fan wheel faster than maximum
cataloged fan rpm. Adjustments to fan speed
significantly effects motor load. If the fan RPM is
changed, the motor current should be checked to
make sure it is not exceeding the motor nameplate
amps.
• Do not allow the power cable to kink or come in
contact with oil, grease, hot surfaces or chemicals.
Replace cord immediately if damaged.
• Verify that the power source is compatible with the
equipment.
• Never open access doors to a duct while the fan is
running.
• The precipitator contains safety electrical interlock
switches at all maintenance access doors. Do not
attempt to defeat these interlocks.
General Safety Information
DANGER
Always disconnect power before working on or near
this equipment. Lock and tag the disconnect switch
or breaker to prevent accidental power up.
CAUTION
When servicing the fan, motor may be hot enough
to cause pain or injury. Allow motor to cool before
servicing.
CAUTION
Do not install this equipment in explosive
atmospheres.