Henny Penny OGA-322 Fryer User Manual


 
© 2006 Henny Penny Corporation, Eaton, OH 45320 USA Revised 11/01/07
Laboratory certifications
Continuing product improvement may subject specifications to change without notice.
PROJECT ITEM NO
www.hennypenny.com
Bidding Specifications
Provide Henny Penny model OEA-322 two-
well electric open fryer or model OGA-322
two-well gas open fryer, 30 lbs. (13.6 kg)
capacity per load, with auto-lift feature,
Computron
®
8000 control, and built-in
filtration system standard.
Materials—cabinet, deck, exhaust stack,
filter drain pan and various fittings are
stainless steel. Fry pots are heavy duty
stainless steel.
Units shall incorporate high-efficiency heat-
exchange design for extremely fast recovery.
Units qualify for the ENERGY STAR
®
mark.
Heating elements encircle the fry pot part-
way up the side, and are not located at the
bottom or below the pot. This design
produces a “cold zone” that extends oil life.
Units shall have two auto lift mechanisms
and timers per well.
Unit’s controller provides for programmable
or manual operation with press-key controls
and LED digital display. Control offers idle and
melt modes, load compensation, filtration
tracking and 7-day history.
Units will include four heavy-duty casters, two
locking.
Units ship with stainless steel Max filtration
screen and 2 PHT filter envelopes, (2) full
baskets, (1) full and (2) half baskets, or (4) half
baskets.
FRONT
MODEL OEA-322 2-well electric
OGA-322 2-well gas
Auto lift open fryers
Capacity
Product 30 lbs. (13.6 kg)
Oil 130 lbs. (59 kg)
Fryer throughput: fries/hr.
Electric 126 lbs. (57.2 kg)
Gas 144 lbs. (65.4 kg)
Electrical
33 3/8 in. (847 mm)
37 3/8 in. (949 mm)
54 5/8 in.
(1387 mm)
Height includes
casters
Dimensions
Width 33 3/8 in. (847 mm)
Depth 37 3/8 in. (949 mm)
Height 54 5/8 in. (1387 mm)
Required clearances
Sides: 6 in. (152 mm) air flow
Back: 6 in. (152 mm) air flow, connections
Front: 30 in. (762 mm) filter pan removal
Crated dimensions
Length 40 in. (1016 mm)
Depth 39 in. (991 mm)
Height 65 in. (1651 mm)
Volume 58.7 cu. ft. (1.66 m³)
Net weight N/A
Crated weight
Electric 469 lbs. (213 kg)
Gas 529 lbs. (240 kg)
Heating
Electric Immersed elements, 28.8 kW
Gas
Natural or liquid petroleum
(4) burners,170,000 BTU/hr (50 kW)
(1) ¾ in. connection
Watts Amps
Volts Phase Cycle/Hz
Per well Total Per well Total
Wire
208 3 60 14400 28800 39.9 79.8 3+G
240 3 60 14400 28800 37.2 74.4 3+G
480 3 60 14400 28800 17.5 35.0 3+G
Two electrical connections required, one for each well. Power cord and plug must be
installed on site by a qualified electrician.
Gas models
120 1 60 N/A 12.0 24.0 2+G
230 1 50 N/A 2.5 5.0 1NG
PLAN
Electric units:
(2) electrical connections,
one per well
Gas units:
(1) ¾ in. gas connection