Hobart D Series Refrigerator User Manual


 
4
LEGS OR CASTERS
WARNING: THE CABINET MUST BE BLOCKED AND
STABLE BEFORE INSTALLING LEGS OR CASTERS.
Legs (Fig. 4)
To install the legs, raise and block the reach-in a minimum of
7" from the floor and thread the legs into the threaded holes on
the bottom of the cabinet. The unit must be level in order to
operate properly. Turn the adjustable feet in or out as required
to level the unit front-to-back and side-to-side.
NOTE: Three-section front opening cabinets come with five
legs; the fifth leg should be placed in the front center threaded
hole. Failure to install these legs in the proper location may
result in damage to the cabinet.
Casters (Fig. 5)
Use casters only on reach-in models that have cord and plug
electrical connections.
Raise and block the cabinet a minimum of 7" from the floor.
Thread the casters into the holes in the bottom of the cabinet
(Fig. 6). Casters with brake should be installed at the front.
Securely tighten the caster with the octagon shaped bolt head
underneath not the round flange on top.
Shelves (Fig. 6)
If purchased, the shelves and shelf clips are shipped with
the cabinet. Insert the shelf clips into the pilaster and
install the shelves. Index holes are provided in the pilaster
to help in leveling the shelves.
Bonus shelves are provided to fill the space between the
shelves. These are positioned and supported by the
shelves.
NOTE: Loosen all thumbscrews which secure shelf
pilasters and light cover(s) prior to placing product in the
cabinet. Thumbscrews should be loose enough to remove
with your fingers so parts can be readily removed for
cleaning without the use of tools. Failure to comply with
this request will invalidate the NSF listing.
Compressor Mounts
Some reach-in refrigeration models have the compressor
specially mounted to help prevent damage during
shipment. If the compressor is mounted on shipping
blocks, remove the shipping blocks before operating the
compressor. If the compressor is mounted on springs,
refer to the tag attached to the compressor.
Fig. 5
Fig. 6
PL-53353
BOLT
Fig. 4
PL-50910
BONUS
SHELF
SHELF
SHELF
CLIP
PILASTER
INDEX
HOLE
COLD AIR
DUCT
RAISE
THREADED HOLE
LOWER
PL-56125