Hobart D Series Refrigerator User Manual


 
5
Condensate Evaporator
D Series units are equipped with an automatic condensate evaporator that requires no drain connection.
ELECTRICAL CONNECTIONS (Cord Connected Reach-Ins) 120Volt, 60 Hertz, 1 Phase
WARNING: THIS MACHINE IS PROVIDED WITH A THREE-PRONGED GROUNDING PLUG. THE
OUTLET TO WHICH THIS PLUG IS CONNECTED MUST BE PROPERLY GROUNDED. IF THE
RECEPTACLE IS NOT THE PROPER GROUNDING TYPE, CONTACT AN ELECTRICIAN.
ELECTRICAL CONNECTIONS (Permanently Connected Reach-Ins)
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE
APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL
ELECTRICAL CODES.
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE
DISCONNECT SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT.
Make electrical connections per the wiring diagram supplied with the unit.
PRE-START CHECKS
REFRIGERANT LINES Check for tubing shifts due to shipping that would cause operating noise,
wear or leaks.
OPERATIONAL CHECK The refrigeration and defrost cycles should be checked for proper
operation before food product is stored in the cabinet.
DEFROST TIMER On freezer units, set the defrost timer as described in Operation.
OPERATION
TEMPERATURE CONTROL The temperature control
is set at the factory but local conditions may necessitate
slight adjustment. To adjust the temperature control, lift up
and remove the front trim panel (Fig. 2). Turn the control
knob (Fig. 7) a small amount at a time. Turning the control
knob in the direction of the arrow lowers the temperature.
The control knob has a marked OFF position which
interrupts power to the compressor and condenser fan
only, not the entire reach-in.
THERMOMETER The drum thermometer (upper right
corner) indicates the cabinet temperature.
Fig. 7
TEMPERATURE
CONTROL
PL-56151