Hobart ML-124061 Freezer User Manual


 
– 9 –
34 35 33
AIR=34 HLD 01:35:45
1. HOLDING COOLER
2. HOLDING FREEZER
2. FREEZE MODE
From the main menu, press [2], when available.
Freeze mode operates exactly like chill mode. Use the menus on
page 7 except
CHILL
is replaced by
FREEZE
. Different target
temperature and air set point may be entered in Set-Up Mode.
Different temperature ranges are available for chill and freeze
modes.
After a Freeze cycle is complete, the cabinet goes into Freezer
Hold mode.
3. DEFROST MODE
From the main menu, press [3].
To begin a manual defrost cycle, press [YES]. Pressing [NO] will
return to the main menu.
The top line of the display indicates defrost mode is in progress.
The coil temperature and the time remaining in the Defrost cycle
are displayed on the bottom line. Once it has begun, the Defrost
cycle cannot be stopped. The Defrost cycle ends when either the
coil temperature reaches the Defrost Termination Temperature or
when the Defrost Termination Time has elapsed (factory setting is
20 minutes). The Buzzer sounds for two minutes or until [MUTE]
is pressed.
Press [YES] and return to the main menu.
NOTE: Different factors influence the ideal frequency of defrost cycles. When you see some
frosting on the coil in the cabinet behind the louvers, a Defrost cycle should be
performed. If the Defrost cycle is skipped, air circulation in the cabinet will be reduced
and chilling or freezing times will increase.
4. HOLD MODE —
From the main menu, press [4].
If the cabinet is a chiller / freezer, this menu selects which holding
air temperature setting is used during a selected Hold mode. After
a chill or freeze cycle, the system automatically selects the
corresponding holding temperature. This menu is omitted if the
cabinet is a chiller only model.
The top row displays the food probe temperatures. The bottom
row displays the air temperature, the Hold mode indicator, and the
time accumulated since the Hold mode began. The compressor
operates to maintain the air temperature at the selected target
temperature in Hold mode. When the temperature is reached,
fans stop, and periodically restart to maintain a uniform internal
temperature.
NOTE: During Hold mode, an automatic Defrost occurs every six hours. To exit Hold mode,
press [STOP] and return to the main menu.
In Hold mode, quick chillers and quick feezers operate like a standard refrigerator or
freezer. Probes are ignored and air temperature is maintained at the selected value.
If the message COOLING TOO SLOW displays during Hold mode, the cabinet needs
service.
READY TO DEFROST
REMOVE FOOD [YES]
UNIT DEFROSTING
COIL=6 00:18:42
DEFROST CYCLE DONE
ACKNOWLEDGE [YES]
FREEZE METHOD:1.AUTO
2.MANUAL 3.EXIT