- 15 -
Refit the caps on the cleaning outlets to seal
them off.
AM-50: Slide in the spray assembly along
the rails on the right and left brackets. Refit
the discharge tube securely on the spray
outlet. Note: A loose fitting may cause a
water leak and improper water spray during
freeze.
AM-100 & AM-150: Slide the water plate
along the mechanism base. Refit the
discharge tube securely on the spray outlet.
A loose fitting may cause a water leak.
(AM
-
50)
(AM-100 & AM-150)
(AM
-
50)
(AM-100 & AM-150)