Cornelius 230 VAC Beverage Dispenser User Manual


 
EIMI Cornelius Inc; 1998
July 21, 1998
569000242
OBSOLETE
IMI CORNELIUS INC g One Cornelius Place g Anoka, MN 55303-6234
Telephone (800) 238-3600 Facsimile (612) 422-3246
INSTALLATION INSTRUCTIONS
VOLTAGE PROTECTOR MODULE KIT (P/N 440000401)
ON
230 VAC, 50Hz VANTAGE POST-MIX DISPENSERS
Read and understand these instructions thoroughly before installing this Voltage Protector Module Kit. Purpose
of the Voltage Protector Module is to shut the Dispenser down should a too low or a too high power voltage con-
dition occur. Retain these instructions as part of your equipment manual.
LOOSE-SHIPPED PARTS
Note: Only qualified personnel should install this Kit.
Unpack and inspect kit. Make sure items are present and in good condition.
Table 1. Loose-Shipped Parts
Item
No. Part No. Name Qty
1 XXXXXXXXX Voltage Protector Module 1
2 560003334 Electrical Wire (brown) 1
3 560003335 Electrical Wire (black) 1
4 560003336 Electrical Wire (blue) 1
5 325282000 Screw, Hex Washer Hd; Self-Drilling, No. 8–18 Thread by 1/2-inch Long 4
KIT INSTALLATION
WARNING: To avoid possible fatal electrical shock or serious injury to Installer, make sure
Dispenser is disconneced from power source before attempting to install this kit.
1. Disconnect electrical power from the Dispenser
2. Remove screw securing the hood, then lift hood straight up off the Dispenser.
3. Remove two screws securing the electrical control box cover, then remove cover for access to the control
board.
NOTE: It may be necessary to relocate the transformer to make room for installation of the VOLTAGE
PROTECTOR MODULE (item 1) on the refrigeration deck as shown in Figure 1.
4. Remove two screws securing the transformer to the refrigeration deck. Discard the two transformer retain-
ing screws.