Cornelius Universal C-750 Beverage Dispenser User Manual


 
9 185211000
2. The Unit should be located in a shaded area for better cooling efficiency.
3. The Unit should be close to a grounded electrical outlet with proper electrical requirements (see Unit
nameplate for electrical requirements).
DRAIN CONNECTIONS
(see Figure 3)
Drip Tray Drain Hose - The DRIP TRAY, as provided, is a closed container and must be emptied periodically. If
permanent drain is desired, cut out center of drain connection on drip tray. Be sure to remove all plastic to open
drain to its maximum inside diameter, eliminating any rough edges which will trap dirt. Install DRIP TRAY (item
3) by inserting rear edge of tray under lip of valve trim panel and lifting up until bottom tray supports are inserted
in square holes provided in front panel. Lock drip tray in place by a light downward pressure. Connect drain
hose below drip tray to drain connection on drip tray. This drain hose runs to inside of Unit and must be routed
out through hole in back of the Unit and must be placed in a waste container.
Water Tank Drain Hose - A drain hose, connected to the bottom of the water tank, is provided to drain water
from the tank. Hose clamp and plug in end of drain hose should be removed only when desired to drain the
tank. This drain hose may be routed out through the hole in back of the Unit to a floor drain or to a waste
container when draining the tank.
Water Tank Overflow Tube - Water tank overflow tube may be routed out through the hole in back of the Unit.
Plug in end of overflow tube should be removed only when ice water bath is being replenished and during initial
forming of a new ice bank.
FILL WATER TANK AND START REFRIGERATION SYSTEM
(see Figure 3)
1. Make sure plug is secure in end of water tank drain hose.
2. Pull release latch on front of the top cover, then lift hinged top cover up into open position.
3. Route Unit product inlet lines coiled in top of Unit, out through the hole in back of Unit.
4. Fill Unit water tank with water as follows:
A. Remove plug from end of water tank overflow tube.
B. Remove water fill hole plug.
C. Fill water tank with water until water starts flowing from water tank overflow tube. USE
LOW-MINERAL-CONTENT WATER WHERE A LOCAL WATER PROBLEM EXISTS.
Do not install plug in end of water tank overflow tube until full ice bank has been formed, as ice
expansion will raise water level in the water tank.
D. Install water fill hole plug.
5. Pull release latch on front of the top cover, then lower hinged top cover into closed position. Release latch
to secure top cover in locked position.
WARNING: The Unit must be electrically grounded to prevent possible fatal electrical shock
or serious injury to operator. The Unit power cord is equipped with a three-prong plug. If a
three-hole (grounded) electrical outlet is not available, use an approved method to ground
the Unit.
6. 115 VAC, 60 Hz Units only Make sure the main power switch, located on the back of the Unit, is in the
‘‘OFF’’ (down) position. Plug Unit power cord into electrical outlet, then place the main power switch in the
ON position.
230 VAC, 50 Hz Unit Plug Unit power cord into electrical outlet.
The compressor, condenser fan motor, and agitator motor will start and begin forming an ice bank. When a
full ice bank has been formed, the compressor and condenser fan motor will stop but the agitator motor will
continue to operate circulating ice water bath in the water tank. Water will continue to drip from the water
tank overflow tube until a full ice bank has been formed, then the tube may be removed from the waste
container and stored inside the unit.