Cornelius Universal C-750 Beverage Dispenser User Manual


 
21 185211000
13. Remove plug from end of water tank overflow tube, then route tube to drain or waste container.
14. 115 VAC, 60 Hz Units only Place Unit main power switch, located on the back of the Unit, in the ‘‘ON’’
(up) position. Make sure compressor, condenser fan motor, and agitator motor are operating.
230 VAC, 50 Hz Unit Plug Unit power cord into electrical outlet.
AGITATOR
MOTOR
UNIT PRODUCT
INLET LINE (4)
ICE BANK CONTROL
SENSING BULB
FIGURE 4. WATER TANK (FOUR-FLAVOR UNIT SHOWN)
15. Pull release latch on front of top cover, then lower hinged top cover into closed position. Release latch to
secure top cover in locked position.
16. Install plug in end of water tank overflow tube after ice bank has been formed and refrigeration system has
cycled off.
CLEANING
DAILY CLEANING OF UNIT
Rinse out sponge with clean water, then wring excess water out of sponge. Wipe off external surfaces of Unit,
then wipe Unit dry with a clean soft cloth. DO NOT USE ABRASIVE CLEANERS.
DAILY CLEANING OF DRIP TRAY
1. Lift drip tray up slightly and at the same time, tip front of drip tray up to disengage its bottom supports from
square holes in Unit front panel. Slide drip tray down to disengage its upper rear edge from under valve
trim panel lip.