Kenmore 233.503632 Ventilation Hood User Manual


 
Ducted Configuration
1. Use 6" round metal duct to connect the
duct collar on the hood to the ductwork
above.
2. Use duct tape to make all joints secure
and air tight.
3. Insert the decorative flues setting them on
the hood.
4. Extend the upper flue to the ceiling and
secure with the 2 screws (C).
-, FASTEN FLUE TO
_,_" UPPER BRACKET
"- WITH SCREWS (C)
DECORATIVE
FLUE
/DUCTTAPE
6"ROUND
METALDUCT
Ductfree Configuration
1. Turn upper flue sect{on upside
down so air vents are at the top.
Slide upper flue section into
lower flue section.
2. Connect the duetfree pienum to
the upper flue section with (4) flat-
head screws (supplied).
3. InstalI the reduction on the
discharge collar.
4. Measure the distance from the
top of the reduction to the ceiling.
Cut a length of 5" round metam
duct 5" shorter than this
dimension.
5. Fit duct section over the ductfree
plenum. For best fit, make sure
duct seam is toward the front.
6. Set duct/flue assembly on hood
with top tilted away from wall.
Reach around flue to engage
bottom of duct with discharge
UPPER AIR UPPER
FLU E SECTION VENTS BRACKET
X (nn upper fUue section)
[
DUCTFREE
PLENUM ....
FLUE SECTION
5"
METAL DUCT
D_SCNARGE
COLLAR
collar on hood. Tilt flue up against wall. Duct seam can be cut to length if necessary.
7. Extend the upper flue to the ceiling and secure with the 2 screws (C).