KitchenAid 1955 Range User Manual


 
Warning
– Fire Hazard
Locate gas supply shut
off valve on the pressure
regulator.
Shut off gas supply before
converting to L.P. gas.
Make all conversions
before turning gas supply
valve back on.
Failure to follow these instructions could result in fire,
exposion or other personal injury.
A. PlAstic cover
B. GAs Pressure reGulAtor cAP with solid end
fAcinG out
c. GAs Pressure reGulAtor cAP with hollow
end fAcinG out
d. wAsher
e. GAs Pressure reGulAtor cAP
Conversion of Regulator to “LP”
on Model 1956 (gas oven)
Remove storage drawer. See page 17.
Locate the regulator at the rear of storage drawer
compartment.
Remove the plastic cover from the regulator cap.
With your fingers, turn the nut counter clockwise.
Do not remove the spring beneath the cap.
Turn the cap over so LP faces up and reinstall into regulator.
Replace plastic cover over regulator cap.
OVEN CONVERSION MODEL 1956
To Convert Oven Bake and Broil Burner
1. Remove oven racks.
2. Use a 1/2” combination wrench to tighten the orifice
hood toward the pin (about 2 to 2-1/2 turns). The oven
bake burner flame cannot be properly adjusted if this
conversion is not made.
A. orifice hood
B. Pin
c. nAturAl GAs: increAse GAs – increAse flAme size (Preset
At fActory for nAturAl GAs)
d. lP GAs: decreAse GAs, deGreAse flAme size.
To Convert Oven Broiler Burner
1. Use a 1/2” combination wrench to tighten the orifice
hood toward the pin (about 2 to 2-1/2 turns. The
oven broil burner flame cannot be properly adjusted
if this conversion is not made. See “Adjust Oven
Broil Burner Flame” section.
2. Reinstall the storage or warming drawer.
3. Complete installation. See “Make Gas Connection”
and “Electronic Ignition System” sections.
Checking for proper cooktop burner and oven bake
burner flame is very important. Natural gas flames do
not have yellow tips.
IMPORTANT: You may have to adjust “LO” setting for
each cooktop burner.
13