KitchenAid 423 Ventilation Hood User Manual


 
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
CABINET OPENING DIMENSIONS
VENTING REQUIREMENTS
KICU265H
KICU285H
Electrical: 120-volt, 60-Hz, AC-only, 15-amp.
electrical supply. Use copper wire only. A time-
delay fuse or circuit breaker and separate circuit is
recommended.
36" and 48" Island Canopy Range Hood
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 4360369 Rev. C
10-15-02
®
8’ (2.4 m) min. -
9’ (2.7 m) max.
ceiling to floor
support
structure
24" (61 cm) min.
bottom of canopy to
cooking surface
canopy
lower
chimney
upper
chimney
36" (91.4 cm)
base cabinet
height
3-1/4" x 10"
(8.3 cm x 25 cm)
through
the roof
roof cap
Horizontal wall venting
3-1/4" x 10"
(8.3 cm x 25 cm)
through the wall
wall cap
Vertical roof venting
The vent system length should not
exceed the lengths shown in the
chart below.
Vent size Maximum length
3-1/4" x 10" 35 ft. (10.7 m)
(8.3 cm x 25 cm)
7" (17.8 cm) round 40 ft. (12.2 m)
8" (20.3 cm) round 50 ft. (15.2 m)
9" (22.9 cm) round 60 ft. (18.3 m)
Vent Piece 3-1/4" x 10" (8.3 cm x 25 cm) 7" (17.8 cm), 8" (20.3 cm)
Rectangular or 9" (22.9 cm) Round
45° elbow 7.0 feet 2.5 feet
(2.1 m) (0.8 cm)
90° elbow 5.0 feet 5.0 feet
(1.5 m) (1.5 m)
90° flat elbow 12.0 feet
(3.7 m)
transition to round 5.0 feet
(1.5 m)
wall cap 0.0 feet
(0.0 m)
3-1/4" x 10”
(8.3 cm x 25 cm)
elbow
wall
cap
Maximum length = 35 ft. (10.7 m)
1 — 90° elbow = 5 ft. (1.5 m)
8 ft. (2.4 m) straight = 8 ft. (2.4 m)
1 — wall cap = 0 ft. (0 m)
Length of 3-1/4" x 10"
(8.3 cm x 25 cm)
system = 13 ft. (4 m)
6 ft. (1.8 m)
2 ft.
(0.6 m)
3-1/4" x 10"
(8.3 cm x 25 cm)
v
ent system
To calculate the length of the system you need, add the
equivalent feet for each vent piece used in the system.
Note: Flexible vent is Not
recommended.
If it is used, each foot of flexible vent
used is equivalent to two feet (61 cm)
of straight metal vent when
calculating the vent system length.
(Example: A flexible elbow equals two
standard elbows.)
36" hood 35-3/8" (89.9 cm) or
48" hood 47-1/4" (120 cm)
overall width
23-5/8" (60 cm)
overall depth
24-5/8" (62.5 cm) min. -
34-3/4" (88.3 cm) max.
overall chimney height
23-5/8"
(60 cm)
lower
chimney
height
1" (2.5 cm) min. -
11-1/8" (23.8 cm) max.
upper chimney height
10-1/4" (26 cm)
canopy height
7 1/16"
(17.9 cm)
10 7/8"
(27.6 cm)
Note: 3-1/4" x 10"
(8.3 cm x 25 cm)
rectangular vent must
be used inside chimney
cover. Round vent will
not fit inside chimney
cover.
Note: 3-1/4" x 10"
(8.3 cm x 25 cm)
rectangular vent must
be used inside chimney
cover. Round vent will
not fit inside chimney
cover.