PRODUCT MODEL SERIES OVERALL DIMENSIONS
CABINET OPENING DIMENSIONS
KEBC167M
Electrical: A four-wire or three-wire, single
phase, 240-volt, 60 Hz, AC-only electrical supply is
required on a separate, 30-ampere circuit, fused
on both sides of the line.Use minimum 8 gauge
copper wire only. A time-delay fuse or circuit
breaker is recommended. A U.L.-listed conduit
connector must be provided at the junction box.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 8301807
02-13-04
36" Built-in Single Oven
®
Cabinet side
view
Electrical supply junction box should be located 3 inches maximum
below the support surface when oven is installed in a wall cabinet. Drill
a 1-inch minimum diameter hole in the right rear or left rear corner of
the support surface to pass the appliance cable through to the junction
box. For undercounter installation, it is recommended that the junction
box be located in the adjacent right or left cabinet. If installing the
junction box on rear wall behind oven, junction box must be recessed
and located in the upper or lower right or left corner of cabinet.
27-1/2"
recessed
height
34-3/8" max.
recessed
width
23" max.
recessed
depth
29" max.
overall
height
35-3/4"
overall width
36" min.
cabinet width
34-1/2"
cutout width
5-1/4" bottom of
cutout to floor
27-3/4"
min.
cutout
height
1-1/2" min.
top of cutout
to underside
of countertop
23-1/4" min.
cutout depth
23" recessed
oven depth
recessed
oven
cabinet
oven
front
36" min.
cabinet width
34-1/2"
cutout
width
1" top of cutout
to bottom of
upper cabinet
door
1-1/2" min.
bottom of
cutout to
top of
cabinet
door
32"
bottom of
cutout to
floor
27-3/4"
min.
cutout
height
Single
undercounter oven
(without cooktop
installed above)