30" Freestanding and Slide-In Gas Range
®
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
CABINET OPENING DIMENSIONS
SLIDE-IN RANGE COUNTERTOP PREPARATION
KGRT600H
KGRT607H
KGST300H
KGST307H
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
The cooktop sides of the slide-in range fit over
the cutout edge of your countertop.
If you have a square finish (flat) countertop
and the opening width is 30", no countertop
preparation is required.
Formed front-edged countertops: Must have
molded edge shaved flat 1/2" from each front
corner of opening.
Tile countertops may need trim cut back
1/2" from each front corner and/or rounded
edge flattened.
If countertop opening width is greater than 30",
adjust the 1/2" dimension.
Countertop must be level. Place level on
countertop, first side to side; then front to
back. If countertop is not level, range will not
be level. Oven must be level for satisfactory
baking conditions.
Slide-in Range
Freestanding
Range
Gas supply:Use 3/4" rigid pipe gas supply
line to the range location. A smaller size pipe on
long runs may result in insufficient gas supply.
With L.P. gas, piping or tubing size can be 1/2"
minimum. If local codes permit, it is
recommended that new flexible metal tubing,
design-certified by AGA or CSA, 4-5 feet long,
1/2-inch or 3/4-inch I.D., be used for connecting
the range to the rigid gas supply line. A 1/2"
male pipe thread is needed for connection to
pressure regulator female pipe threads. An
easily accessible individual manual shutoff valve
must be located in the same room, but external
to the range.
Electrical:120-volt, 60 Hz, AC-only, 10 amp,
electrical supply, fused on both sides of the line.
A separate circuit is recommended. A time-delay
fuse or circuit breaker is recommended.
Ref. 9758571
04-20-04
Cooktop sides of range fit over
edges of countertop opening.
Formed or tiled
countertop trimmed
1/2" (1.3 cm) back at
front corners of
countertop opening.
30-7/8"
(78.4 cm)
1/2"
(1.3 cm)
30"
(76.2 cm)
opening
width
22-5/8"
(57.5 cm)
8-1/4"
(21 cm)
1"
(2.54 cm)
spacer
30" (76.2 cm)
range width
44-3/8"
(112.7 cm)
36-1/8"
(91.8 cm)
cooktop
height
27-3/4"
(70.5 cm)
depth
with
handle
1-1/2"
(3.8 cm)
1"
(2.54 cm)
spacer
30" (76.2 cm)
rear vent width
36-1/8"
(91.8 cm)
cooktop
height
27-3/4"
(70.5 cm)
depth
with
handle
30"
(76.2 cm)
width
25" countertop depth and 24" base cabinet depth,
36" countertop height
Freestanding or Slide-in Range
7/8" (2.2 cm) min.
required between
cabinet opening and
door or hinge opening
4" (10.2 cm) min. clearance from
both sides of range to side wall
or other combustible material.
Outlet should be
located within the
18" x 10"
(45.7 x 25.4 cm)
shaded area
6" (15.2 cm)
10" (25.4 cm)
For minimum
clearance to
cooktop, see
NOTE*
.
9" (22.9 cm)
18" (45.7 cm)
upper side cabinet
to countertop
30" (76.2 cm) cabinet
opening width
13" (33 cm) max.
upper cabinet depth
3" (7.6 cm)
2-1/2"
(6.4 cm)
2-1/2" (6.4 cm)
2" (5.1 cm)
30" (76.2 cm)
opening width
24" (61 cm)
18"
(45.7 cm)
Floor gas line
opening if directly
below regulator
Gas line opening
should be located
within this shaded area
*
NOTE:
24" (61 cm) min. when bottom of wood or metal cabinet is
protected by not less than 1/4" (6.4 mm) flame retardant millboard
covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm)
stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) min. clearance between the top of the cooking platform
and the bottom of an unprotected wood or metal cabinet.