KitchenAid KUDI02IR Dishwasher User Manual


 
Undercounter Dishwasher
®
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
CABINET OPENING DIMENSIONS
KUDC02IR
KUDI02CR
KUDI02FR
KUDI02IR
KUDJ02CR
KUDK02CR
KUDL02FR
KUDL02IR
KUDM02IS
KUDP02CR
KUDP02FR
KUDP02FS
KUDP02IR
KUDP02SR
KUDR02FS
KUDS02FR
KUDS02FS
KUDS02IS
KUDS02SR
KUDS03FS
KUDU02FR
KUDU02VR
KUDW02FR
Electrical: 120-volt, 60-Hz, AC-only, 15- or
20-amp. fused electrical supply. Use copper wire
only. A time-delay fuse or circuit breaker and
separate circuit is recommended.
Water: A hot water line with 20-120 psi
(138-862 kPa) water pressure. Water temperature
must be 120°F (49°C) at dishwasher. Use 3/8" O.D.
copper tubing with compression fitting or flexible
stainless steel braided fill line (1/2" minimum plastic
tubing is optional but not recommended). Use a 90°
elbow with 3/8" N.P.T. external pipe threads on one
end to connect to water inlet valve. Do not solder
within 6" (15.2 cm) from water inlet valve.
Drain: Use the new drain hose supplied with your
dishwasher. If this is not suitable, use a new drain
hose with a maximum length of 12 feet (3.7 m)
that meets all current AHAM/IAPMO test
standards, is resistant to heat and detergent, and
fits the drain connector of the dishwasher. Must
have a high drain loop 20 inches (50.8 cm) above
the subfloor or floor. Connect drain hose to waste
tee or disposer inlet above drain trap in house
plumbing and 20 inches (50.8 cm) minimum
above the floor. An air gap must be used if the
drain hose is connected to house plumbing lower
than 20 inches (50.8 cm) above subfloor or floor.
Use 1/2" minimum I.D. drain line fittings.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 8574116
07-26-06
24-7/8" (63.2 cm)
3/4" (1.9 cm)
insulation – may be
compressed (not used
on all models)
Side view
Rear view
24-1/2"
(62.2 cm)
21" (53.3 cm)
23-7/8"
(60.6 cm)
33-7/8"
(86 cm) min. with
wheels removed
Cut holes in shaded area of cabinet walls or floor as specified below:
water line – 1/2" (1.3 cm)
drain line – 1-1/2" (3.8 cm)
direct wire – 3/4" (1.9 cm)
power supply cord – 1-1/2" (3.8 cm)
* Measured from the lowest point on the underside of countertop. May be
reduced to 33-7/8" (86 cm) by removing wheels from dishwasher.
** Minimum, measured from narrowest point of opening.
*** May be increased to 6-7/8" (17.5 cm) if height of opening is 34-1/2" (87.6 cm)
at its lowest point.
‡ Both sides
9"
(22.9 cm)
10"
(25.4 cm)
6" ***
(15.2 cm)
6" ***
(15.2 cm)
3-1/4"
(8.3 cm)
2-3/4"
(7 cm)
34"
(86.4 cm)
min.*
2"
(5.1 cm)
2"
(5.1 cm)
All surfaces must be free
from intrusions
2"
(5.1 cm)
3-1/4"
(8.3 cm)
3-1/4"
(8.3 cm)
2-3/4"
(7 cm)
3-1/4"
(8.3 cm)
24" (61 cm)
min.
24" (61 cm)
**
5-1/2"
(14 cm)
3-1/2"
(8.9 cm)