3. General specifications
3-1
2)%
6"/2)
No. Item Spec. Related spec.
1 Operating temp.
0
+55
2 Storage temp. -25
+70
3 Operating moist. 5~95% RH, non-condensing
4 Storage moist. 5~95% RH, non-condensing
For discontinuous vibration
Frequency Acceleration Amplitude Number
10
f
57Hz
- 0.075mm
57
f
150Hz 9.8
-
For continuous vibration
Frequency Acceleration Amplitude
10
f
57Hz
- 0.035mm
5Vibration
57
f
150Hz 4.9
-
Each 10 times in
X,Y,Z directions
ICE 1131-2
6 Impact
•
Max. impact acceleration:147
(15G)
•
Authorized time : 11ms
•
Pulse wave : Sign half-wave pulse(each 3 times in X,Y,Z
directions)
IEC 1131-2
Square wave
Impulse noise
1,500V
Test spec. reference
within LG Industrial
Systems
Static electric
discharging
Voltage : 4kV(Contact discharging)
IEC 1131-2,
IEC 801-2
Radiation
electric field
noise
27
500 MHz, 10V/m
IEC 1131-2,
IEC 801-3
Segment
Power
module
Digital
input/
output
(24V or
more)
Digital input/output
(less than
24V)Analog
input/output
communication
interface
7Noise
Fast
transient/burst
noise
Voltage 2kV 1kV 0.25 kV
IEC 1131-2,
IEC 801-4
8 Ambient conditions No corrosive gas and dust
9 Height Up to 2,000m
10 Pollution level 2 or less
11 Cooling type Natural air cooling
1. IEC(International Electro-technical Commission) : International non-governmental association, which
establishes international standards in the field of electric and electronics.
2. Pollution level : This is an indication showing pollution of surrounding environment, which determines
insulation performance of device, and generally the pollution level 2 means the conditions in which only
non-conductive pollution occurs.
But, temporary conduction may occur according to condensing.
Remark
3.1 General specifications of communication module(Fnet)