ELECTRICAL CONNECTIONS
3-WIRE CONNECTION WITH
A POWER SUPPLY CORD
• The middle (neutral or ground) wire, which
is white, of a 3 wire power cord or a 3 wire
conduit has to be connected to the middle
post of the main terminal block. The remaining
two wires of the power cord or conduit have to
be connected to the outside posts of the main
terminal connection block.
- Failure to do so can result in electrical shock,
severe personal injury or death.
WARNING
Install the power cord as follows:
For power cord installations, Hook the strain relief over
the power cord hole (1
3
/
8
”) located below the rear of
oven. Insert the power cord through the strain relief and
tighten it. (Refer to Figure 7.)
DO NOT install the power cord without a strain relief.
1. Remove the lower 3 screws from the terminal block
and retain them. (Refer to Figure 8.)
2. Insert the 3 screws through each power cord terminal
ring and into the lower terminals of the terminal block.
Make sure that the center (neutral) wire, which is
white, is connected to the center lower position of the
terminal block.
3. Tighten 3 screws securely into the terminal block. Do
not remove the ground strap connections.
4. Refer to page 13
Cord strain relief
Power cord
Conduit
connection
plate
Separate Strain Relief
before installation
Assemble the strain relief
to the 1
3
/
8
” opening in
Conduit connection plate
FIGURE 7
3-wire connection
Terminal
block
Conduit
connection plate
Black White Red
FIGURE 8
* If screws are not tightened securely, it can result in
electrical spark and severe personal injury or death.