LG Electronics LRE3021ST Range User Manual


 
12
ELECTRICAL CONNECTIONS
4-WIRE CONNECTION: CONDUIT









- Failure to do so can result in electrical shock,
severe personal injury or death.
WARNING
1. Follow the instructions under “Install the conduit as
follows” on page 11 to correctly install the strain relief.
DO NOT install the conduit without a strain relief.
2. Loosen the 2 lower left and right screws from the
terminal block. (Refer to Figure 12.) Remove the lower
2 center screws.
3. Remove ground strap and discard as shown in Figure
12. Do not discard any screws.
4. Attach the ground bare wire (green) end to range
frame and secure it in place with the ground screw
(Refer to figure 12.)
5. Insert the bare wire (white/neutral) end through the
center terminal block opening.
6. Insert the two side bare wire ends into the left and the
right terminal block opening. Tighten the 3 screws
securely into the terminal block. (approximately
35 - 50 IN-LB)
7. Refer to page 13.
4-wire connection
Remove
ground
strap and
discard
Terminal
block
Wire
ends
Conduit
connection plate
Black White Red
Ground
strap
Ground
Wire
Ground
Screw

* If screws are not tightened securely, it can result in
electrical spark and severe personal injury or death.
Replace the access cover on the back of the range. To
replace the wire cover, insert the two tabs into the
openings located below the opening and tighten the
three screws.
Access cover