LG Electronics LRE3023SB Range User Manual


 
10
ELECTRICAL CONNECTIONS
4-WIRE CONNECTION: CONDUIT
1. Follow the instructions under “Install the conduit as
follows” on page 8 to correctly install the strain relief.
DO NOT install the conduit without a strain relief.
2. Loosen the 2 lower left and right screws from the
terminal block. (Refer to Figure 12.) Remove the lower
2 center screws.
3. Remove ground strap and discard as shown in Figure
12. Do not discard any screws.
4. Attach the ground bare wire end to range frame and
secure it in place with the ground screw (Refer to
gure 12.)
5. Insert the bare wire (white/neutral) end through the
ce
nter terminal block opening.
6. Insert the two side bare wire ends into the left and the
right terminal block opening. Tighten the 3 screws
securely into the terminal block. (approximately
35 - 50 IN-LB)
7. Refer to page 11.
4-wire connection
Remove
ground
strap and
discard
Terminal
block
Wire
ends
Conduit
connection plate
Black White Red
Ground
strap
Ground
Wire
Ground
Screw
FIgURE 12