Maytag MER6755AAB/Q/S/W Double Oven User Manual


 
Troubleshooting Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless
testing requires power.
10 16023416 ©2004 Maytag Services
CAUTION
!
Verify proper grounding before checking for trouble.
Be careful of the high voltage circuit.
Discharge the high voltage capacitor.
When checking the continuity of the switches or of the high voltage transformer, disconnect one lead wire from
these parts and then check continuity with the AC plug removed. To do otherwise may result in a false reading
or damage to your meter.
Do not touch any part of the circuit on the printed circuit board, since static electric discharge may damage the
control panel. Always touch yourself to ground while working on this panel to discharge any static charge built
up on your body.
Control Systems Troubleshooting
Description of Error Codes
The Diagnostic Code Display Mode allows viewing of the error diagnostic codes.
Each error code consists of four digits. The following table describes the function of each digit.
Digit Description
1
st
Primary System: 1 – Local to the control circuit board
3 – Sensor or meat probe
4 – Control input
9 – Door lock
2
nd
Measurable: d – Diagnostic: measurable parameter
c – Control related, replace control
3
rd
Secondary System: Sequential numbering
4
th
Oven Cavity: 1 – Upper oven (or single cavity oven)
2 – Lower oven
c – Control specific
Diagnostic Code Display Mode is accessed via the Quick Test Mode. To view the last 5 error codes, enter the Quick
Test Mode by pressing and holding the
UPPER CANCEL
and
UPPER BROIL
pads for 3 seconds within 5 minutes
of power-up. Diagnostic Code Display Mode may be activated only when applying power to the control.