Middleby Marshall PS200-R68 Oven User Manual


 
3
SECTION 1
DESCRIPTION
NOTE
Wiring Diagram is contained at the back of this Manual
and is also located inside of the
machinery compartment.
.
SERIES PS200-R68
ELECTRICAL SPECIFICATIONS
GAS HEATED OVENS
Main Blower Control Phase Frequency Amperage Poles Wires
& Elements Circuit Draw
Voltage Voltage
208-240V 120V 1 Ph 50/60 Hz 4.1 Amp 3 Pole 4 Wire
(2 hot,1 neut,1 grd)
208V 120V 1 Ph 50/60 Hz 4.1 Amp 2 Pole 3 Wire
Export Transformer (2 hot,1 grd)
200V 120V 1 Ph 50/60 Hz 4.1 Amp 2 Pole 3 Wire
Export Transformer (2 hot,1 grd)
220-240V 120V 1 Ph 50/60 Hz 4.1 Amp 2 Pole 3 Wire
Export Transformer (2 hot,1 grd)
ELECTRIC HEATED OVENS
Main Blower Control Phase Frequency Amperage Poles Wires
& Elements Circuit Draw
Voltage Voltage
208-240V 120V 3 Ph 50/60 Hz 75 Amp 4 Pole 5 Wire
(3 hot, 1 neut, 1 grd)
HEATER AMPERAGE
Voltage kW Amp Average Amps
208 27 70 37 37 37
220 23.5 67 30 30 30
230 25.7 63 31 31 31
240 27 61 33 33 33
220-240V 120V 3 Ph 50/60 Hz 75 Amp 3 Pole 4 Wire
Transformer (3 hot, 1 grd)
HEATER AMPERAGE
Voltage kW Amp Average Amps
220 23.5 67 30 30 30
240 27 61 33 33 33
380V 120V 3 Ph 50/60 Hz 50 Amp 4 Pole 5 Wire
Export Transformer (3 hot, 1 neut, 1 grd)
HEATER AMPERAGE
Voltage kW Amp Average Amps
380 27 38 22 22 22
400-416V 120V 3 Ph 50/60 Hz 50 Amp 4 Pole 5 Wire
Export Transformer (3 hot, 1 neut, 1 grd)
HEATER AMPERAGE
Voltage kW Amp Average Amps
415 27 35 28 28 28