Miele G600 Dishwasher User Manual


 
Technical Information
G600 & G800 Electronic Dishwashers
4.18 Condenser Drying (UKT)
Does not apply to all dishwasher models
4.18.1 Operation
An air inlet port is located on the back / left area of the cavity ceiling.
An air duct is fitted to the port and attaches to the Condenser
Assembly.
During the Drying portion of a program, moist air within the cabinet is
drawn through the Condenser Assembly via the Condenser Fan (M2).
As the cabinet air passes the Cold Water Reservoir (inside the
condenser) water vapor forms and exits the condenser (as water) via
the port on the left wall of the cabinet.
The cooling bank within the Condenser Assembly utilizes water from
the intake / softening system controlled by the electronic via the
Condenser Control Valve (Y6).
4.18.2 Technical Data
Control valve (Y6) AC 120 Hz
Cold Water Reservoir 750 ml