Electrical connection
Electrical connection of the ap-
pliance should be made by a quali-
fied electrician in accordance with
all local and national ordinances.
Note to the installer:
Please leave these instructions with
the consumer.
Power supply:
Please check the dataplate for
240 VAC; 60 Hz or
208 VAC; 60 Hz
Caution:
Disconnect the cooktop from the
main power supply before servicing
or installing. To reduce the risk of
electric shock, make sure that the
appliance is properly grounded
after installation.
Warning:
This appliance must be grounded.
For CDN only
The appliances are provided with 3 ter-
minal leads: 1 black wire, 1 red wire
and 1 green wire which have to be con-
nected to a separate overcurrent pro-
tection device (fusebox).
All hot wires (black and red) have to be
fused individually before connecting
them to the main power supply leads.
Use 15 Amp fuses for appliances
rated 240 VAC.
Connect black terminal wire to L1
(black) and red terminal wire to L 2
(red). The green terminal wire (ground)
has to be connected directly to the
equivalent colored power supply leads.
All connections must be done in a
proper way.
See also wiring diagram provided
with the appliance.
For USA only
The appliance is provided with a 3wire
cord.1 black wire (L 1), 1 red wire (L 2)
and 1 green wire (GND) which should
be connected to a dedicated line in-
side of an approved junction box. Con-
nect the black wire to L 1, the red wire
to L 2 and the green wire to GND.
Also, see the circuit diagram pro-
vided with the appliance.
Electrical connection
16