Mitsubishi Electronics fre700 Microwave Oven User Manual


 
18
Wiring for CC-Link communication
2.5.3 Connection cable and plug
In the CC-Link system, use CC-Link dedicated cables.
If the cable used is other than the CC-Link dedicated cable, the performance of the CC-Link system is not guaranteed.
For the specifications of the CC-Link dedicated cable, refer to the website of the CC-Link Partner Association.
Website of the CC-Link Partner Association http://www.cc-link.org/
y One-touch communication connector plug (as of December 2009)
Refer to the following table for the plug required to fabricate a cable on your own.
(1) Cable-end treatment
Apply the following treatment to the CC-Link dedicated cable that is inserted to a one-touch communication connector plug.
(2) Plug cover check
Check that a plug cover is snapped into a plug.
(3) Cable insertion
Lift up the tail of the plug cover, and fully insert a cable. Insert
different signal wires to the one-touch communication connector
plug as shown in the right figure.
Model Manufacturer
A6CON-L5P Mitsubishi Electric Corporation
35505-6000-B0M GF 3M
1. Cut the sheath. 2. Separate shielding wires from the drain wire. Cut the shielding
wires.
3. Cut the aluminum tape and braid. 4. Straighten the drain wire and twist it from the root.
(Twist seven times or more per 3cm.)
REMARKS
y Where possible, round the cable tip that is cut off with a tool such as nippers. If the cable is not rounded, it may get caught in
the middle of a plug, without fully entering into the plug.
y If required, apply an insulation treatment to the shielding wire area where it is not covered by the one-touch communication
connector plug.
Note
y Do not push the plug cover onto the plug before inserting a cable. Once crimped, the plug cover cannot be reused.
REMARKS
y Insert the cable fully. Failure to do so may cause a crimping failure.
y A cable sometimes comes out of the head of the cover.
In that case, pull the cable a little so that the cable stays under the plug cover.
Drain wire
Shielding wires
Drain wire
DA (Blue)
DB (White)
DG (Yellow)
3cm
Drain wire (AWG20)
DA (Blue)
DB (White)
DG (Yellow)
Plug
Plug cover
54321
NC
SLD
DA (Blue)
DB (White)
DG (Yellow)
Signal name