Mitsubishi Electronics FR-F700P Microwave Oven User Manual


 
2
Step of operation
1.2 Step of operation
The inverter needs frequency command and start command. Frequency command (set frequency) determines the
rotation speed of the motor. Turning ON the start command starts the motor to rotate.
Refer to the flow chart below to perform setting.
·When protecting the motor from overheat by the inverter, set Pr.9 Electronic thermal O/L relay (Refer to
page 52)
·To drive a general-purpose motor with the rated motor frequency of 50Hz, set Pr.3 Base frequency
(Refer to page 53)
CAUTION
Check the following points before powering ON the inverter.
· Check that the inverter is installed correctly in a correct place. (Refer to page 8)
· Check that wiring is correct. (Refer to page 9)
· Check that no load is connected to the motor.
Connect a switch, relay, etc.
to the control circuit
terminal block of the inverter
to give a start command. (External)
Start command using the PU connector and
RS-485 terminal of the inverter and plug-in
option (Communication)
Set from the
PU (FR-DU07/
FR-PU04/FR-PU07).
(PU)
Change frequency
with ON/OFF switches
connected to terminals
(multi-speed setting)
Perform frequency
setting by a current
output device
(Connection across
terminals 4 and 5)
Perform frequency
setting by a voltage
output device
(Connection across
terminals 2 and 5)
Set from the
PU (FR-DU07/
FR-PU04/FR-PU07).
Change of frequency
with ON/OFF switches
connected to terminals
(multi-speed setting)
Perform frequency
setting by a current
output device
(Connection across
terminals 4 and 5)
Perform frequency
setting by a voltage
output device
(Connection across
terminals 2 and 5)
(External) (External) (External)
(PU) (External) (External) (External)
Start command with
on the operation panel (PU)
Step of operation
f
o
p
Step of operation
Installation/mounting
Wiring of the power
supply and motor
How
to give a start
command?
How to
give a frequency
command?
How to
give a frequency
command?
ON
Time
(S)
(Hz)
Frequency
command
Frequency command
Inverter
output
frequency
: Initial setting
Frequency
{Refer to page 54} {Refer to page 57} {Refer to page 60} {Refer to page 59}
{Refer to page 11}
{Refer to page 8}
Refer to Chapter 4 of the Instruction Manual (Applied) .
{Refer to page 61} {Refer to page 65} {Refer to page 69} {Refer to page 67}