Model No.: SGL150CXN
Client to provide the following connections:
Oven requires direct wiring from switchboard. Note: element wattage may vary by 5%
Water connection ½” BSP. Drainage connection ½”copper drain pipe
Power: 3P + N + E, 400 - 415 volt, 50 Hz, 2.42kW
Gas requirements : 200 MJ/hr
Natural gas supply 2.0 kpa to burner gas valve (3/4” BSP connection)
LP gas supply 3.0 kpa to burner gas valve (3/4” BSP connection)
Connections: 1/2” BSP water supply connection and ½” copper drain located at rear of oven
Dimensions: Width:1820mm
Depth: 1720mm (includes canopy)
Height: 2700mm (includes canopy)
Weight: 850kg
Note: Oven supply does not include canopies and flues as required by relevant authorities.
Bends or offsets in the flue restrict gas velocity and must be allowed for when designing
the flue height and diameter which will be dependent on the building and local
conditions.
Chimney flue to be taken to atmosphere 127mm diam.
Oven exhaust flue 200mm dia (canopy models), 100mm dia (non canopy models)
Clearance: 50mm clearance is required at back and sides of unit
Minimum 2900mm ceiling height
Floor: A concrete or tile surface is preferred.
The floor area is to be flat to within 3mm over whole floor area.
Access: Oven is supplied partially assembled to be fully erected on site.
Largest piece if partially assembled 2130mm H x 1820mm W x 1220mm D
Largest piece if unassembled 2130mm H x 1820mm W x 660mm D
TECHNICAL SPECIFICATIONS
TURBOFAN 150
(Gas)
.
.
d
ri
v
e
n
b
y
i
n
n
o
v
ati
o
n
a
nd
c
u
s
t
om
e
r
sa
t
i
s
f
a
c
ti
o
n
Australia
Moffat Pty Limited
email: vsales@moffat.com.au
www.moffat.com.au
Free Call 1800 023 953
SGL150CXN 0403V1
New Zealand
Free Call 0800 663 328
nz
nz
Moffat Limited
email: sales@moffat.co.
www.moffat.co.
In line with policy to continually develop and improve its products, Moffat reserves the right to change specifications and design without notice.