NuTone 8110 Ventilation Hood User Manual


 
NOTE: The knockouts of the outside sleeve are
removable to allow clearance space for the outlet
box.
INSTALLING THE WALL SLEEVES
For installation into wood: nail outside panel to
sheathing through holes provided in flange of
outside panel.
For installation into brick: grout unit into place so
that panel is flush with brick.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE. ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the manufacturer. If you
have questions, contact the manufacturer.
B. Before servicing or cleaning unit, switch power off at service panel and
lock service panel to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the service panel.
CAUTION:
For general ventilating use only. Do not use to exhaust hazardous or
explosive materials and vapors.
INSTALLATION INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction.
B. Sufficient air is needed for proper combusition and exhausting of gases
through the flue (chimney) of fuel burning equipment to prevent back
drafting. Follow the heating equipment manufacturer's guideline and
safety standards such as those published by the National Fire Protection
Association (NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and the local code
authorities.
C. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must be marked as
appropriate for the application.
F. NEVER place a switch where it can be reached from a tub or shower.
WARNING: To reduce the risk of shock, disconnect power before
servicing.
CAUTION: To reduce risk of fire and to properly exhaust air, be sure to
vent air outside. Do not vent exhaust air into spaces within walls or
ceilings or into attics, crawl spaces or garages.
WARNING: To reduce the risk of fire or electric shock, do not use this fan
with any solid state speed control.
NOTE: Cutout dimension: 9
1
/
8
" dia. for model 8010 - 11
1
/
8
" dia. for 8110.
If your installation presents a problem that is not explained here or
if any part of these instructions is not clear, consult a professional
installer. If you are not familiar with methods of installing electrical
wiring, or if you are not certain as to the correctness of any step or
procedure described here, secure the services of a qualified
electrician.
INSTALLING THE “A” UNIT
The “A” Unit consists of the wall sleeve assembly, outlet box and outlet
box cover.
ADJUSTING THE WALL SLEEVES
1. Refer to Figure 1. Pull the inside sleeve out to the desired wall thickness
for the the circular flange to be flush with the finished wall.
2. Align the slots in the inside sleeve to the holes in the outside sleeve and
fasten together with screws furnished.
INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
8" Pull-Chain Model 8010
10" Pull-Chain Model 8110
FIGURE 1
FIGURE 2
FIGURE 3