NuTone QT130 Ventilation Hood User Manual


 
Architectural & Engineering Specifications
March 2004
QuieTTest Twin
Blower Ventilator
(For Ceiling Use)
MODEL: QT130
DESCRIPTION
For bathrooms up to 110 sq. ft. (10.2M
2
), other rooms up
to 150 sq. ft. (13.9M
2
).
Sturdy brown-enamel steel housing is lined with
sound-deadening foam for quiet operation.
Low RPM motor plugs into prewired junction box.
Motor and twin blowers dynamically balanced
for smooth, quiet operation.
Vents horizontally or vertically with 3
1
4" x 10" duct.
Duct collar with quiet backdraft damper included.
Installs easily between 16" O.C. joists with slotted
mounting brackets. Slots on the sides of the housing
provide alternative mounting.
Wiring knockouts located on the top and back
of the housing.
Refer to NuTone's catalog for a complete line
of accessories to effectively adapt this Fan
to your construction requirements.
Energy Star
®
Qualified.
DESIGN FEATURES
HVI Air Delivery: Vertically: 120 CFM (56.6LS).
Horizontally: 130 CFM (61.3LS).
HVI Sound Level: .9 Sones vertically or 1.0 horizontally.
Dimensions: Housing: 14
1
4" L x 10" W x 9" D
(36.2CM X 25.4CM X 22.8CM).
Grille: 16
1
2" L x 12
3
32" W x
5
8" D
(41.9CM X 30.7CM X 1.6CM).
Material & Finish: Housing: Galvanized steel.
Grille: White Polymeric.
Motor: Thermally protected. 120 v AC, 60 Hz,
.5 amps.
Blower Wheel: Two (2) aluminum, electronically
balanced.
Duct Size: 3
1
4" x 10".
Electrical Rating: 120v, 60Hz, 0.6Amp
INSTALLATION
Not for use in kitchens. Do not mount over range,
bathtub or shower stall.
The ventilator consists of the housing, mounting
brackets, junction box, power unit/blower assembly,
damper section and grille assembly.
Suitable for use with solid-state speed control.
Speed control must be purchased separately;
refer to NuTone’s catalog.
Installation Instructions are provided with each unit.
ARCHITECT'S SPECIFICATIONS
Twin-Blower Ventilator shall be Model QT130 as
manufactured by NuTone according to listed specifications.
Unit shall ventilate 120 CFM when ducted vertically
or 120 CFM when ducted horizontally at .10” S.P.
at a sound level of .90 sones. Housing shall measure
14
1
4" x 10" x 9" deep and connect to 3
1
4" x 10" duct.